SJ700
2
Inverter
Configur
ing Dr
iv
e
P
a
ra
met
e
rs
3–71
NOTE:
Parameters P044 to P049 are available only in inverters with manufacturing code
x8K xxxxxx xxxxx or later. The manufacturing code is printed on the product specifications
labels, located on the front and side of the inverter housing.
P055
Pulse train frequency scale
1.0 to 50.0 (kHz)
25.0
25.0
25.0
✘ ✔
P056
Pulse train frequency filter time constant
0.01 to 2.00 (seconds)
0.10
0.10
0.10
✘ ✔
P057
Pulse train frequency bias
-100. to 100. (%)
0.
0.
0.
✘ ✔
P058
Pulse train frequency limit
0. to 100. (%)
100.
100.
100.
✘ ✔
P060
to
P067
Multi-stage position setting 0
to Multi-stage position setting 7
Reverse side to forward side (upper four
digits including sign “-”)
0
0
0
✔ ✔
P068
Zero-return mode selection
LOW
00
Low speed
00
00
00
✔ ✔
Hi1
0 1
High speed
Hi2
02
High speed 2
P069
Zero return direction
selection
FW
00
Forward
00
00
00
✔ ✔
RW
0 1
Reverse
P070
Low speed zero return frequency
0.00 to 10.00 (Hz)
0.00
0.00
0.00
✔ ✔
P071
High speed zero return frequency
0.00 to 99.99 / 100.0 to maximum frequency
setting, 1st motor (Hz)
0.00
0.00
0.00
✔ ✔
P072
Forward position range
0 to 268435455 (when P012 = 02),
0 to 1073741823 (when P013 = 03) (upper
four digits)
268435455
✔ ✔
P073
Reverse position range
-268435455 to 0 (when P012 = 02),
1073741823 to 0 (when P013 = 03)
(upper four digits)
-268435455
✔ ✔
P074
Teaching selection
X00
00
X00
00
00
00
✔ ✔
X01
0 1
X01
X02
02
X02
X03
03
X03
X04
04
X04
X05
05
X05
X06
06
X06
X07
07
X07
P100
to
P131
Easy sequence user parameters U(00) to
U(31)
0. to 9999., 1000 to 6553 (10000 to 65535)
0.
0.
0.
✔ ✔
Func.
Code
Name/
Description
Keypad
Range and Settings
Defaults
Run
Mode
Edit
Lo Hi
SRW
OPE
FEF2
FE2
(EU)
FUF2
FU2
(USA)
FF2
F2
(Jpn)