SJ700
2
Inverter
Appendix B
B–65
C156
— Logic output 5 operator
R/W
00 . AND
01 . OR
02 . XOR (exclusive OR)
14A0h
05280
0, 1, 2
—
C157
— Logic output 6 function A
R/W
All programmable output
functions available (except
LOG1 to LOG6)
14A1h
05281
—
—
C158
— Logic output 6 function B
R/W
14A2h
05282
C159
— Logic output 6 operator
R/W
00 . AND
01 . OR
02 . XOR (exclusive OR)
14A3h
05283
0, 1, 2
—
C160
— Terminal [1] input
response time setting
R/W
0. to 200. (x 2 milliseconds)
14A4h
05284
0 to 200
2 ms
C161
— Terminal [2] input
response time setting
R/W
0. to 200. (x 2 milliseconds)
14A5h
05285
0 to 200
2 ms
C162
— Terminal [3] input
response time setting
R/W
0. to 200. (x 2 milliseconds)
14A6h
05286
0 to 200
2 ms
C163
— Terminal [4] input
response time setting
R/W
0. to 200. (x 2 milliseconds)
14A7h
05287
0 to 200
2 ms
C164
— Terminal [5] input
response time setting
R/W
0. to 200. (x 2 milliseconds)
14A8h
05288
0 to 200
2 ms
C165
— Terminal [6] input
response time setting
R/W
0. to 200. (x 2 milliseconds)
14A9h
05289
0 to 200
2 ms
C166
— Terminal [7] input
response time setting
R/W
0. to 200. (x 2 milliseconds)
14AA
h
05290
0 to 200
2 ms
C167
— Terminal [8] input
response time setting
R/W
0. to 200. (x 2 milliseconds)
14ABh
05291
0 to 200
2 ms
C168
— Terminal [FW] input
response time setting
R/W
0. to 200. (x 2 milliseconds)
14ACh
05292
0 to 200
2 ms
C169
— Multi-speed position deter-
mination time
R/W
0. to 200. (x 2 milliseconds)
14AD
h
05293
0 to 200
2 ms
—
(Reserved)
—
—
14AEh
to
1500h
05294
to
05376
—
—
Holding Registers, “C” Group Intelligent Terminal Functions
Func. Code
Name
R/W
Description
Network Data
Register
Range
Res.
hex
dec.