SJ700
2
Inverter
Configur
ing Dr
iv
e
P
a
ra
met
e
rs
3–29
Elevator Accel/
Decel Curves
Parameters A150 to A153 affect the slope of the acceleration and deceleration for the elevator-
related S curves.
A143
Calculation symbol
ADD
00
ADD (A input + B input)
00
00
00
✘ ✔
Calculates a value based on
the A input (A141 selects)
and the B input (A142
selects)
SUB
0 1
SUB (A input – B input)
MUL
02
MUL (A input x B input)
A145
ADD frequency
—
—
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00
0.00
0.00
✘ ✔
A146
ADD direction select
FW
00
Plus (adds A145 value to output
frequency)
00
00
00
✘ ✔
RV
0 1
Minus (subtracts A145 value from output
frequency)
Func.
Code
Name/
Description
Keypad
Range and Settings
Defaults
Run
Mode
Edit
Lo Hi
SRW
OPE
FEF2
FE2
(EU)
FUF2
FU2
(USA)
FF2
F2
(Jpn)
Func.
Code
Name/
Description
Range and Settings
Defaults
Run
Mode
Edit
Lo Hi
FEF2
FE2
(EU)
FUF2
FU2
(USA)
FF2
F2
(Jpn)
A150
EL-S curve accel. ratio 1
Range is 0. to 50. (%)
25.
25.
25.
✘ ✘
A151
EL-S curve accel. ratio 2
Range is 0. to 50.
25.
25.
25.
✘ ✘
A152
EL-S curve decel. ratio 1
Range is 0. to 50.
25.
25.
25.
✘ ✘
A153
EL-S curve decel. ratio 3
Range is 0. to 50.
25.
25.
25.
✘ ✘