SJ700
2
Inverter
Appendix B
B–45
A024
H Multi-speed 4 setting
R/W
Defines nth additional speed
121Eh
04638
0 or start
freq. to
max. freq.
0.01 Hz
A024
L
121Fh
04639
A025
H Multi-speed 5 setting
R/W
Defines nth additional speed
1220h
04640
0 or start
freq. to
max. freq.
0.01 Hz
A025
L
1221h
04641
A026
H Multi-speed 6 setting
R/W
Defines nth additional speed
1222h
04642
0 or start
freq. to
max. freq.
0.01 Hz
A026
L
1223h
04643
A027
H Multi-speed 7 setting
R/W
Defines nth additional speed
1224h
04644
0 or start
freq. to
max. freq.
0.01 Hz
A027
L
1225h
04645
A028
H Multi-speed 8 setting
R/W
Defines nth additional speed
1226h
04646
0 or start
freq. to
max. freq.
0.01 Hz
A028
L
1227h
04647
A029
H Multi-speed 9 setting
R/W
Defines nth additional speed
1228h
04648
0 or start
freq. to
max. freq.
0.01 Hz
A029
L
1229h
04649
A030
H Multi-speed 10 setting
R/W
Defines nth additional speed
122Ah
04650
0 or start
freq. to
max. freq.
0.01 Hz
A030
L
122Bh
04651
A031
H Multi-speed 11 setting
R/W
Defines nth additional speed
122Ch
04652
0 or start
freq. to
max. freq.
0.01 Hz
A031
L
122Dh
04653
A032
H Multi-speed 12 setting
R/W
Defines nth additional speed
122Eh
04654
0 or start
freq. to
max. freq.
0.01 Hz
A032
L
122Fh
04655
A033
H Multi-speed 13 setting
R/W
Defines nth additional speed
1230h
04656
0 or start
freq. to
max. freq.
0.01 Hz
A033
L
1231h
04657
A034
H Multi-speed 14 setting
R/W
Defines nth additional speed
1232h
04658
0 or start
freq. to
max. freq.
0.01 Hz
A034
L
1233h
04659
A035
H Multi-speed 15 setting
R/W
Defines nth additional speed
1234h
04660
0 or start
freq. to
max. freq.
0.01 Hz
A035
L
1235h
04661
—
(Reserved)
—
—
1236h
04662
—
—
—
(Reserved)
—
—
1237h
04663
—
—
A038
— Jog frequency setting
R/W
Defines limited speed for jog
1238h
04664
0 to 999
0.01 Hz
Holding Registers, “A” Group Standard Functions
Func. Code
Name
R/W
Description
Network Data
Register
Range
Res.
hex
dec.