SJ700
2
Inverter
Configur
ing Dr
iv
e
P
a
ra
met
e
rs
3–57
26
OL2
Overload notice advance
signal (2)
Output current is more than the set Threshold 2 for the
overload signal (set with C111)
27
Odc
Analog [O] disconnect
detect
Input signal level at terminal [O] is below threshold (set with
B070)
28
OIDc
Analog [OI] disconnect
detect
Input signal level at terminal [OI] is below threshold (set with
B071)
29
O2Dc
Analog [O2] disconnect
detect
Input signal level at terminal [O2] is below threshold (set with
B072)
31
FBV
PID feedback second
stage output
Stage #1 inverter is indicating to Stage # inverter that the
Process Variable (PV) is in saturation. The system needs
Stage #2 output contribution to stabilize system control.
32
NDc
Network detection signal
The communications watchdog timer (period specified by
C077) has timed out
33
LOG1
Logic output 1
Boolean operation specified by C144 has a logical “1” result
34
LOG2
Logic output 2
Boolean operation specified by C147 has a logical “1” result
35
LOG3
Logic output 3
Boolean operation specified by C150 has a logical “1” result
36
LOG4
Logic output 4
Boolean operation specified by C153 has a logical “1” result
37
LOG5
Logic output 5
Boolean operation specified by C156 has a logical “1” result
38
LOG6
Logic output 6
Boolean operation specified by C159 has a logical “1” result
39
WAC
Capacitor life warning
Capacitor bank on the main board needs replacement
40
WAF
Low cooling fan speed
Cooling fan is enabled but it is rotating below normal speed
41
FR
Starting contact signal
ON while the inverter receives a FW or REV command
42
OHF
Heat sink overheat
warning
Inverter heat sink temperature is above the threshold set by
C064
43
LOC
Low output current signal
Output current to motor is below threshold set by C039
44
MO1
General output 1
Easy sequence function, general output 1
45
MO2
General output 2
Easy sequence function, general output 2
46
MO3
General output 3
Easy sequence function, general output 3
47
MO4
General output 4
Easy sequence function, general output 4
48
MO5
General output 5
Easy sequence function, general output 5
49
MO6
General output 6
Easy sequence function, general output 6
50
IRDY
Inverter ready signal
Inverter is ready to accept commands (FW, REV, JOG, etc.)
51
FWR
Forward rotation signal
Inverter output is driving motor in forward direction
52
RVR
Reverse rotation signal
Inverter output is driving motor in reverse direction
53
MJA
Major failure signal
Inverter trip caused by internal hardware error
54
WCO
[O] terminal window
comparator
[O] input is within comparator window set by B060 and B061
55
WCOI
[OI] terminal window
comparator
[OI] input is within comparator window set by B063 and
B064
Output Function Summary Table
Option
Code
Terminal
Symbol
Function Name
Description