Multi-speed and
Jog Frequency
Settings
The SJ700
2
inverter has the capability to store and output up to 16 preset frequencies to the
motor (A020 to A035). As in traditional motion terminology, we call this
multi-speed profile
capability. These preset frequencies are selected by means of digital inputs to the inverter. The
inverter applies the current acceleration or deceleration setting to change from the current
output frequency to the new one. The first multi-speed setting is duplicated for the second
motor settings (the remaining 15 multi-speeds apply only to the first motor).
The jog speed setting is used whenever the Jog command is active. The jog speed setting range
is arbitrarily limited to 10 Hz to provide safety during manual operation. The acceleration to the
jog frequency is instantaneous, but you can choose from six modes for the best method for
stopping the jog operation.
A013
[O]–[L] input active range start voltage
0. to [O]-[L] input active range end
voltage (%)
0.
0.
0.
✘ ✔
The starting point for the voltage input range
A014
[O]–[L] input active range end voltage
[O]-[L] input active range start voltage to
100. (%)
100.
100.
100.
✘ ✔
The ending point for the voltage input range
A015
[O]–[L] input start frequency
enable
0-EXS
00
Use A011 start value
01
01
01
✘ ✔
OHz
0 1
Use 0 Hz
A016
External frequency filter time constant
n = 1 to 30 (where n = number of
samples for average); 31=500ms filter
8.
8.
8.
✘ ✔
A017
Easy sequence function
enable
OFF
00
Disable
00
00
00
✘ ✘
ON
0 1
Enable
Func.
Code
Name/
Description
Keypad
Range and Settings
Defaults
Run
Mode
Edit
Lo Hi
SRW
OPE
FEF2
FE2
(EU)
FUF2
FU2
(USA)
FF2
F2
(Jpn)
Func.
Code
Name/
Description
Keypad
Range and Settings
Defaults
Run
Mode
Edit
Lo Hi
SRW
OPE
FEF2
FE2
(EU)
FUF2
FU2
(USA)
FF2
F2
(Jpn)
A019
Multi-speed operation selec-
tion
BINARY
00
Binary; up to 16-stage speed using
4 intelligent terminals
00
00
00
✘ ✘
BIT
0 1
Single-bit; up to 8-stage speed using
7 intelligent terminals
A020
Multi-speed frequency setting
0 to 360 (Hz)
A020 = Speed 0 (1st motor)
0.00
0.00
0.00
✔ ✔
Defines the first speed of a multi-speed profile
A220
Multi-speed frequency setting, 2nd motor
0 to 360 (Hz)
A220 = Speed 0 (2nd motor)
0.00
0.00
0.00
✔ ✔
Defines the first speed of a multi-speed profile
for 2nd motor
A320
Multi-speed frequency setting, 3rd motor
0 to 360 (Hz)
A320 = Speed 0 (3rd motor)
0.00
0.00
0.00
✔ ✔
Defines the first speed of a multi-speed profile
for 3rd motor
A021
to
A035
Multi-speed frequency settings
(for multiple motors)
0 to 360 (Hz)
A021 = Speed 1...
A035 = Speed 15
0.00
0.00
0.00
✔ ✔
Defines 15 additional speeds