The 400V models from –1850 to –4000HFU2/HFE2 (250 to 525 HP) include a DC reactor and
ferrite core.
Footnotes for the preceding tables and the table that follows:
Note 1:
The protection method conforms to JEM 1030.
Note 2:
The applicable motor refers to Hitachi standard 3-phase motor (4-pole). When using
other motors, care must be taken to prevent the rated motor current (50/60 Hz) from
exceeding the rated output current of the inverter.
Note 3:
The output voltage decreases as the main supply voltage decreases (except when
using the AVR function). In any case, the output voltage cannot exceed the input
power supply voltage.
Note 4:
To operate the motor beyond 50/60 Hz, consult the motor manufacturer for the
maximum allowable rotation speed.
Note 5:
When SLV is selected, please set the carrier frequency higher than 2.1 kHz.
Note 6:
At the rated voltage when using a Hitachi standard 3-phase, 4-pole motor (when
selecting sensorless vector control—SLV).
Note 7:
The braking torque via capacitive feedback is the average deceleration torque at the
shortest deceleration (stopping from 50/60 Hz as indicated). It is not continuous
regenerative braking torque. The average decel torque varies with motor loss. This
value decreases when operating beyond 50 Hz. If a large regenerative torque is
required, the optional regenerative braking resistor should be used.
Note 8:
The frequency command will equal the maximum frequency at 9.8V for input voltage
0 to 10 VDC, or at 19.6 mA for input current 4 to 20 mA. If this characteristic is not
satisfactory for your application, contact your Hitachi sales representative.
Note 9:
The storage temperature refers to the short-term temperature during transport.
Note 10:
Conforms to the test method specified in JIS C0050 (1999). For the model types
excluded in the standard specifications, contact your Hitachi sales representative.
Note 11:
NEMA 1 applies up to 22kW. An optional wire-entry conduit box is required for
0.4kW to 55kW models to meet NEMA 1 rating.
Item
400V Class Specifications
SJ700
2
inverters,
400V models
U.S. version
900HFU2
1100HFU2
1500HFU2
1850HFU2
3150HFU2
4000HFU2
European ver.
9000HFE2
1100HFE2
1320HFE2
1850HFE2
3150HFE2
4000HFE2
Applicable motor size *2
HP
125
150
200
250
425
525
kW
90
110
150
185
315
400
Rated capacity, kVA, 400 / 480V
121.9/146.3
150.3/180.4
180.1/216.1
256 / 308
416 / 499
554 / 665
Rated input voltage
3-phase (3-wire) 380 to 480V +10/-15%, 50/60 Hz ±5%
Rated input current (A)
194
239
286
389
630
840
Rated output voltage *3
3-phase (3-wire): 380 to 480V (corresponding to input voltage)
Rated output current (A)
176
217
260
370
600
800
Overload capacity, output current (A)
50% for 60 sec., 200% for 0.5 sec.
50% for 60 sec., 180% for 0.5 sec.
Inv. efficiency at 100% rated output, %
95.2
95.2
95.2
96.5
96.2
96.3
Inverter Watt loss,
approximate (W)
at 70% output
3375
3900
4670
4700
8000
10500
at 100% output
4800
5550
6650
6700
11500
15000
DCL efficiency at 100% rated output, %
—
—
—
99.9
99.9
99.9
DCL Watt loss,
approximate (kW)
at 70% output
—
—
—
0.1
0.1
0.1
at 100% output
—
—
—
0.2
0.2
0.2
Dynamic braking
approx. % torque,
short time stop *7
w/o braking unit
8%
8%
8%
10%
10%
10%
with braking unit
Refer to separate DB Unit instruction manual or contact your Hitachi distributor
DC braking
Variable operating frequency, time, and braking force
Electrical filtering
Built-in EMC filter and zero-phase reactor
External DC reactor and ferrite core
Weight
kg / lb
55 / 121
55 / 121
70 / 54
140 / 308
210 / 463
360 / 792