Analog Input Operation
Oper
ations
a
nd Moni
tor
ing
4–64
The following tables show the available analog input settings. Parameters A006, A005, and
input terminal [AT] determine the External Frequency Command input terminals that are avail-
able and how they function. The Trim Frequency input [O2]—[L] is available (when check
marked) for some settings. Other settings make the reverse direction (in addition to forward)
available for bipolar input settings (when check marked). A bipolar input responds to positive
input voltages with a forward motor rotation, and to negative input voltages with reverse motor
rotation.
The table below applies when the [AT] input function is not assigned to
any
intelligent input
terminal. The A005 setting, normally used in conjunction with an [AT] input, is ignored.
CAUTION:
Whenever the [AT] input function is
not
assigned to any input terminal and
reverse rotation is not desired or is unsafe, be sure to set A006 = 01. This setting makes the
[O2] input unipolar only.
A006
A005
[AT]
External Frequency
Command Input
Trim Frequency
Command Input
Reverse avail.
(bipolar input)
00
OR
03
00
OFF
[O]
✘
✘
ON
[OI]
✘
✘
01
OFF
[O]
✘
✘
ON
[O2]
✘
✔
01
00
Example
1
OFF
[O]
[O2]
✘
ON
[OI]
[O2]
✘
01
OFF
[O]
[O2]
✘
ON
[O2]
✘
✔
02
00
Example
2
OFF
[O]
[O2]
✔
ON
[OI]
[O2]
✔
01
OFF
[O]
[O2]
✔
ON
[O2
✘
✔
—
02
OFF
[O]
[O2]
✘
ON
Keypad pot.
[O2]
✘
03
OFF
[OI]
[O2]
✘
ON
Keypad pot.
[O2]
✘
04
OFF
[O2]
✘
✔
ON
Keypad pot.
[O2]
✘
A006
A005
[AT]
External Frequency
Command Input
Trim Frequency
Command Input
Reverse avail.
(bipolar input)
00
—
(not
assigned
to any
input
terminal)
[O2]
✘
✔
01
—
Summation of
[O] and [OI]
[O2]
✘
02
—
Summation of
[O] and [OI]
[O2]
✔
03
—
Summation of
[O] and [OI]
✘
✘