SJ700
2
Inverter
Configur
ing Dr
iv
e
P
a
ra
met
e
rs
3–41
B098
01, 02
B099, C085
Thermistor function
B050
01
B051 – B054
Instantaneous power failure
B120
01
B121 – B126
External brake control
Function
Code
Data
Resulting Non-displayed
Functions (when B37 = 01)
Notes
C021 – C025,
C026
02, 06
C042, C043
Frequency arrival signal
03
C040, C041
Overload advance notice
07
C055 – C058
Over-torque
21
C063
Zero-speed detection signal
24, 25
C045, C046
Frequency arrival signal
26
C011
Overload advance notice 2
H002
00
H020 – H024
Motor constant
01, 02
H030 – H034
Motor constant (auto-tuning)
H202
00
H220 – H224
Motor constant
01, 02
H023 – H0234
Motor constant (auto-tuning)
P010
01
P011 – P023, P025 – P027
Expansion card function
Function
Code
Data
Resulting Non-displayed
Functions (when B37 = 01)
Notes
Func.
Code
Name/
Description
Keypad
Range and Settings
Defaults
Run
Mode
Edit
Lo Hi
SRW
OPE
FEF2
FE2
(EU)
FUF2
FU2
(USA)
FF2
F2
(Jpn)
B040
Torque limit selection
4-SET
00
4-quadrant mode
00
00
00
✘ ✔
TM
0 1
Selected by two input terminals (see
p.
4–30
)
O2
02
From analog [O2] input (0 to 10V =
0 to 200%)
OP1
03
From expansion card 1
OP2
04
From expansion card 2
B041
Torque limit (1) (forward-driving in
4-quadrant mode)
150%
150
0. to 200. (%)
150.
150.
150.
✘ ✔
no
no
Disable torque limit
B042
Torque limit (2) (reverse-regenerat-
ing in 4-quadrant mode)
150%
150
0. to 200. (%)
150.
150.
150.
✘ ✔
no
no
Disable torque limit
B043
Torque limit (3) (reverse-driving in
4-quadrant mode)
150%
150
0. to 200. (%)
150.
150.
150.
✘ ✔
no
no
Disable torque limit
B044
Torque limit (4) (forward-regenerat-
ing in 4-quadrant mode)
150%
150
0. to 200. (%)
150.
150.
150.
✘ ✔
no
no
Disable torque limit