Introduction
Appendix C
C–2
Introduction
This appendix lists the user-programmable parameters for the SJ700
2
series inverters and the
default values for European, U.S. and Japanese product types. The right-most column of the
tables is blank so you can record values you have changed from the default. This involves just a
few parameters for most applications.
Parameter Settings for Keypad Entry
SJ700
2
series inverters provide many functions and parameters that can be configured by the
user. We recommend that you record all parameters that have been edited, in order to help in
troubleshooting or recovery from a loss of parameter data.
Main Profile
Parameters
}
This information is printed on
the specification label located
on the right side of the inverter.
Inverter model
MFG. No.
SJ700
“F” Group Parameters
Default Setting
User
Setting
Func.
Code
Name
FEF2, FE2
(Europe)
FU2, FU2
(U.S.A.)
FF2, F2
(Japan)
F001
Output frequency setting
0.00
0.00
0.00
F002
Acceleration (1) time setting
30.0
30.0
30.0
F202
Acceleration (1) time setting, 2nd motor
30.0
30.0
30.0
F302
Acceleration (1) time setting, 3rd motor
30.0
30.0
30.0
F003
Deceleration (1) time setting
30.0
30.0
30.0
F203
Deceleration (1) time setting, 2nd motor
30.0
30.0
30.0
F303
Deceleration (1) time setting, 3rd motor
30.0
30.0
30.0
F004
Keypad Run key routing
00
00
00