NOTE:
An input terminal configured for option code 18 ([RS] Reset command) cannot be
configured for normally closed operation.
Intelligent Input
Terminal
Overview
Each of the eight intelligent terminals may be assigned any of the options in the following
table. When you program one of the option codes for terminal assignments C001 to C008, the
respective terminal assumes the function role of that option code. The terminal functions have a
symbol or abbreviation, which we use to label a terminal using that function. For example the
“Reverse Run” command is [RV]. The physical label on the terminal block connector is simply
1
,
2
,
3
,
4
,
5
,
6, 7, or 8
. However, schematic examples in this manual also use the terminal
function symbol (such as [RV]) to show the assigned option. The option codes for C011 to
C019 determine the active state of the logical input (active high or active low).
Summary Table
- This table shows all forty-four intelligent input functions at a glance.
Detailed descriptions of these functions, related parameters and settings, and example wiring
diagrams are in
“Using Intelligent Input Terminals” on page 4–13
.
C015
Terminal [5] active state
NO
00
Normally open (N.O.)
00
00
00
✘ ✔
NC
0 1
Normally closed (N.C.)
✘ ✔
C016
Terminal [6] active state
NO
00
Normally open (N.O.)
00
00
00
✘ ✔
NC
0 1
Normally closed (N.C.)
✘ ✔
C017
Terminal [7] active state
NO
00
Normally open (N.O.)
00
00
00
✘ ✔
NC
0 1
Normally closed (N.C.)
✘ ✔
C018
Terminal [8] active state
NO
00
Normally open (N.O.)
00
00
00
✘ ✔
NC
0 1
Normally closed (N.C.)
✘ ✔
C019
Terminal [FW] active state
NO
00
Normally open (N.O.)
00
00
00
✘ ✔
NC
0 1
Normally closed (N.C.)
✘ ✔
Func.
Code
Name/
Description
Keypad
Range and Settings
Defaults
Run
Mode
Edit
Lo Hi
SRW
OPE
FEF2
FE2
(EU)
FUF2
FU2
(USA)
FF2
F2
(Jpn)
Input Function Summary Table
Option
Code
Terminal
Symbol
Function Name
Description
01
RV
Reverse Run/Stop
Puts the inverter in Run Mode, motor runs reverse
02
CF1
Multi-speed select,
Bit 0 (LSB)
Binary encoded speed select, Bit 0
03
CF2
Multi-speed select,
Bit 1
Binary encoded speed select, Bit 1
04
CF3
Multi-speed select,
Bit 2
Binary encoded speed select, Bit 2
05
CF4
Multi-speed select,
Bit 3 (MSB)
Binary encoded speed select, Bit 3
06
JG
Jogging
Puts the inverter in Run Mode, output to motor runs at jog
parameter frequency A038
07
DB
External Signal for DC
Injection Braking
Applies DC braking during deceleration