Monitoring Trip Events, History, & Conditions
T
roub
leshooting
and Maintenance
6–10
Note 6:
The inverter will not accept reset commands input via the RS terminal or entered by
the STOP/RESET key. Therefore, turn off the inverter power.
Note 7:
The inverter applied for 004 to 110L/H will not accept reset commands input via the
RS terminal or entered by the STOP/RESET key. Therefore, turn off the inverter
power.
Note 8:
The inverter will not accept the reset command entered from the digital operator.
Therefore, reset the inverter by turning on the RS terminal.
NOTE:
If an EEPROM error (E08) occurs, be sure to confirm the parameter data values are
still correct.
E41.-
ModBus
communica-
tion error
If time-out occurs because of line discon-
nection during the communication in
ModBus-RTU mode, the inverter will
display the error code shown on the left.
(The inverter will trip according to the
setting of C076.)
•
Check whether the communication speed
setting is correct.
•
Check whether the wiring distance is
appropriate (check the connections).
NET.ERR
E60.-
to
E69.-
Option 1 error
The inverter detects errors in the option
board mounted in the optional slot 1. For
details, refer to the instruction manual for
the mounted option board.
•
Check whether the option board is
mounted correctly (check the board
mounting).
•
Check whether the option board is used
correctly (refer to the instruction manual
for the option board SJ-FB, SJ-DG, or
SJ-DN).
OP1-0
OP1-9
OPE / SRW
Display
Name
Description
Troubleshooting and
Corrective Action