ModBus Data Listing
Append
ix
B
B–58
B088
— Restart mode after FRS
R/W
00 . Restart from 0Hz
01 . Restart from frequency
detected from actual speed
of motor
02 . Restart from active matching
frequency
135Bh
04955
0, 1, 2
—
—
(Reserved)
—
—
135Ch
04956
—
—
B090
— Dynamic braking usage
ratio
R/W
0.0 to 100.0 (%)
Set = 0.0 to disable dynamic
braking
135Dh
04957
0 to 1000
0.1 %
B091
— Stop mode selection
R/W
00 . DEC (decelerate and stop)
01 . FRS (free run to stop)
135Eh
04958
0, 1
—
B092
— Cooling fan control
R/W
00 . Fan always ON
01 . Fan ON during RUN,
OFF during STOP
135Fh
04959
0, 1
—
—
(Reserved)
—
—
1360h
04960
—
—
—
(Reserved)
—
—
1361h
04961
—
—
B095
— Dynamic braking control
R/W
00 . Disable
01 . Enable during RUN only
02 . Enable always
1362h
04962
0, 1, 2
—
B096
— Dynamic braking activa-
tion level
R/W
330 to 380 (V) (200V class),
660 to 760 (V) (400V class)
1363h
04963
330 to 380
660 to 760
1 V
—
(Reserved)
—
—
1364h
04964
—
—
B098
— Thermistor for thermal
protection control
R/W
00 . Disable
01 . Enable-PTC thermistor
02 . Enable-NTC thermistor
1365h
04965
0, 1, 2
—
B099
— Thermal protection level
setting
R/W
Thermistor resistance threshold
at which trip occurs
1366h
04966
0 to 9999
1
Ω
B100
— Free-setting V/f freq. (1)
R/W
0. to Free-setting V/f freq. (2)
1367h
04967
0 to V/f 2
1 Hz
B101
— Free-setting V/f voltage (1)
R/W
0.0 to 800.0 (V)
1368h
04968
0 to 8000
0.1 V
B102
— Free-setting V/f freq. (2)
R/W
0. to Free-setting V/f freq. (3)
1369h
04969
0 to V/f 3
1 Hz
B103
— Free-setting V/f voltage (2)
R/W
0.0 to 800.0 (V)
136Ah
04970
0 to 8000
0.1 V
B104
— Free-setting V/f freq. (3)
R/W
0. to Free-setting V/f freq. (4)
136Bh
04971
0 to V/f 4
1 Hz
B105
— Free-setting V/f voltage (3)
R/W
0.0 to 800.0 (V)
136Ch
04972
0 to 8000
0.1 V
B106
— Free-setting V/f freq. (4)
R/W
0. to Free-setting V/f freq. (5)
136Dh
04973
0 to V/f 5
1 Hz
B107
— Free-setting V/f voltage (4)
R/W
0.0 to 800.0 (V)
136Eh
04974
0 to 8000
0.1 V
B108
— Free-setting V/f freq. (5)
R/W
0. to Free-setting V/f freq. (6)
136Fh
04975
0 to V/f 6
1 Hz
B109
— Free-setting V/f voltage (5)
R/W
0.0 to 800.0 (V)
1370h
04976
0 to 8000
0.1 V
B110
— Free-setting V/f freq. (6)
R/W
0. to Free-setting V/f freq. (7)
1371h
04977
0 to V/f 7
1 Hz
B111
— Free-setting V/f voltage (6)
R/W
0.0 to 800.0 (V)
1372h
04978
0 to 8000
0.1 V
B112
— Free-setting V/f freq. (7)
R/W
0. to 400.0 (V)
1373h
04979
0 to V/f 8
1 Hz
B113
— Free-setting V/f voltage (7)
R/W
0.0 to 800.0 (V)
1374h
04980
0 to 8000
0.1 V
Holding Registers, “B” Group Fine Tuning Functions
Func. Code
Name
R/W
Description
Network Data
Register
Range
Res.
hex
dec.