ModBus Data Listing
Append
ix
B
B–72
P047
— DeviceNet polled I/O:
Input instance number
R/W
70, 71, 101
1631h
05681
70, 71,
101
—
P048
— Inverter action on
DeviceNet idle mode
R/W
00..Trip
01..Decelerate and trip
02..Hold last speed
03..Free run stop
04..Decelerate and stop
1632h
05682
0 to 4
—
P049
— Motor poles setting for
RPM
R/W
00 to 38 (even numbers only)
1633h
05683
0 to 19
1 =
2 poles
—
— (Reserved)
—
—
1634h
to
1638h
05684
to
05688
—
—
P055
— Pulse train frequency span
R/W
1.0 to 50.0 (kHz)
1639h
05689
10 to 500
0.1 kHz
P056
— Pulse train frequency time
constant
R/W
0.01 to 2.00 (seconds)
163Ah
05690
1 to 200
0.01 sec.
P057
— Pulse train frequency bias
R/W
-100. to 100. (%)
163Bh
05691
-100 to
100
1 %
P058
— Pulse train frequency limit
R/W
0. to 100. (%)
163Ch
05692
0 to 100
1 %
—
(Reserved)
—
—
163Dh
05693
—
—
P060
H Multi-stage position
setting 0
R/W
Reverse side to forward side
(upper four digits including
sign “–”)
163Eh
05694
—
—
P060
L
R/W
163Fh
05695
P061
H Multi-stage position
setting 1
R/W
Reverse side to forward side
(upper four digits including
sign “–”)
1640h
05696
—
—
P061
L
R/W
1641h
05697
P062
H Multi-stage position
setting 2
R/W
Reverse side to forward side
(upper four digits including
sign “–”)
1642h
05698
—
—
P062
L
R/W
1643h
05699
P063
H Multi-stage position
setting 3
R/W
Reverse side to forward side
(upper four digits including
sign “–”)
1644h
05700
—
—
P063
L
R/W
1645h
05701
P064
H Multi-stage position
setting 4
R/W
Reverse side to forward side
(upper four digits including
sign “–”)
1646h
05702
—
—
P064
L
R/W
1647h
05703
P065
H Multi-stage position
setting 5
R/W
Reverse side to forward side
(upper four digits including
sign “–”)
1648h
05704
—
—
P065
L
R/W
1649h
05705
P066
H Multi-stage position
setting 6
R/W
Reverse side to forward side
(upper four digits including
sign “–”)
164Ah
05706
—
—
P066
L
R/W
164Bh
05707
P067
H Multi-stage position
setting 7
R/W
Reverse side to forward side
(upper four digits including
sign “–”)
164Ch
05708
—
—
P067
L
R/W
164Dh
05709
P068
— Home position mode
selection
R/W
00..Low
01..High
02..High 2
164Eh
05710
0, 1, 2
—
P069
— Home position direction
selection
R/W
00..Forward
01..Reverse
164Fh
05711
0, 1
—
Holding Registers, “P” Group Expansion Card Functions
Func. Code
Name
R/W
Description
Network Data
Register
Range
Res.
hex