background image

Summary of Contents for WF-600T Series

Page 1: ...Pure Sine Wave Power Inverter User s Manual i EIIIO 0 0 iWRIJ OMt WORLD FRIENDSHIP CO LTD Sales Phone 574 295 4268 FAX 574 295 4139 Warehouse 574 294 8997 Fax 574 294 8698 Warranty 800 900 2468 ...

Page 2: ... 3 The rear panel interface 8 3 4 The remote control panel 9 4 Installation 10 4 1 AC safety grounding 10 4 2 GFCI receptacle 10 4 3 Hardwire 11 4 4 Making DC Wiring Connections 11 12 5 Operating 13 5 1 Controls and indicators 13 5 2 System status LEDs 14 6 Information 15 6 1 Troubleshooting Guide 15 6 2 WFCO Power Inverter 16 6 3 Exclusionsand limitations 16 6 4 Warranty 16 Copyright This manual ...

Page 3: ...tments containing batteries or flammable materials or in locations which require ignition protected equipment This includes any space containing generator fuel tanks or joints fittings or other connection between components of the fuel system 1 2 PrecautionsWhen Working with Batteries 1 2 1 If battery acid contacts skin or clothing wash immediately with soap and water If acid enters eye immediatel...

Page 4: ... series output Once the AC utility is restored the relay is energized and the load is automatically reconnected to AC utility WF 600T series is available with 12 24 Vdc Input and 120 Vac 60 Hz Output and there are 2 versions With Hardwire Part No WF 600TH 1XX provide with hardwired installation With GFCI Part No WF 600TG 1XX This provides with the GFCI safety receptacle easier to plug in the appli...

Page 5: ...or sensitive equipments II Built in advance microprocessor to make friendly interface with user II Dual AC outlets or hardwire AC connection model option II Smart remote controller II 3 LED indicators with tri color display all operation status II UL 458 approval and FCC class B Protection II Battery over voltage and under voltage protections II Over temperature protection II Over load protection ...

Page 6: ...120V RMS 10 4 Input Voltage Regulation 10 5 15 21 0 30 VDC VDC Input Level Indicator Red Orange Green LED Load Level Indicator Red Orange Green LED Power Status Red Green LED Overload Short Circuit Reverse Polarity Fuse Protection Over Under Input Voltage Over Temperature AC Inout Circuit Breaker GFCI Circuit Breaker 7Amp Transfer switch 1OAmp Transfer Time 48 msec Safety UL458 EMC FCC Class B Rem...

Page 7: ...3 Basically Descriptions 3 1 Mechanical drawinfJ s 1 I r C INPUT A G I X3C SJT AC CD 0 1 T N d n 1 n J 7D5 I 610 I 6 Qj J I Q 1 HARD IRE 1 I 6ID I 6 i Inl Inl t i i GFCI 6 ...

Page 8: ...l unit put the on off switch to remote 3 2 2 AC input Circuit Breaker The lAmp circuit breaker protects the model from overload When an overland condition exists the circuit breaker stops to supply output AC grid power To reset push the circuit breaker switch and then the model will be back to a normal operation the source fault should be corrected prior reset 3 2 3 Remote port Connect RJ 11wiring...

Page 9: ...3 3 The rear 2 anel interface AC INPUT CQ n 3 3 1 Ventilation Do not obstruct allows at least 2 to 3 inches of clearance for airflow 3 3 2 AC input source Plug into AC source directly 8 ...

Page 10: ...remote controland decides to present either the R O For Ignition lockout function Pinjumper Open R O F PinJumper Short Ignitionlockoutfunction The wiremust be placed witha properlysized 12 Voltfuse Connect RJ 11wirewiththe remote port infront of panel Ignition Lockout function The Ignition lockout function is to turn the InverterOFF when the auxiliaryinputwiringconnects withthe ACCand 12 Voltsis a...

Page 11: ...he same way that the neutral conductor from the utility is tied to ground at the AC breaker panel For models configured with a transfer relay while AC utility powers presenting and he WF 600T Inverter is in bypass mode this connection neutral of the WF 600T Inverter s AC output to input safety ground is not presented so that the utility neutral is only connected to ground at your breaker panel as ...

Page 12: ...d be high quality copper wiring and keep cable length as short as possible the maximum length is 6 feet that plenty handle the current required from the electrical codes or regulations If cables are not an adequate gauge too narrow or much longer the inverter performance decreased DC voltage drop such as poor surge capability low input voltage warnings and shutdowns will be caused frequency so the...

Page 13: ...J lJ IJ r BATTERY WF 600T WARNING The installation of a fuse must be on positive cable Failure to place a fuse on cables running between the Inverter and battery may cause damage to the inverter and will void warranty 12 Model No Wire AWG Inline Fuse WF 600TD 112 4 100A WF 600TD 124 6 50A ...

Page 14: ...current once to all the loads 5 1 Controls and indicators The ON OFF switch is turns on oft the control circuit of the power inverter If connect to power inverter the WF 600T Inverter operates input voltage ranges as follows 10 5 to 15 0 VDC for 12V models 21 0 to 30 0 VDC for 24V models The WF 600T Inverter indicates DC voltage status as follows 13 Model DC Input over DC Input under DC Input unde...

Page 15: ... 9 21 0 21 8 Red 10 9 11 3 21 8 22 6 Orange 11 3 12 0 22 6 24 0 Green 12 0 14 0 24 0 28 0 Orange Blink 14 0 14 7 28 0 29 4 Red Blink 14 7 t 29 4 t LED Status Load Condition Dark 0 30W Green 30W 200W Orange 200W 450W Red 450W 580W Red Blink Over 580W LED Status Power Status Green Supply AC power from an external AC source Orange Supply AC power from an inverter Red Blinking Fast OVP over voltage Re...

Page 16: ...ed fast b Power status light is blinked slowly Over input voltage Low input voltage Solutions Check input voltage Reduce input voltage Recharge battery Check connections and cable c Power status light is blinked Intermittently Thermal shutdown Improve ventilation Make sure ventilation openings in inverter are not obstructed Reduce ambient temperature d Power status light is glowed steadily Short c...

Page 17: ...t apply to the following Any Power Inverter that has been repaired or altered by an unauthorized person Any damage caused by misuse faulty installation testing negligence or accident or any Power Inverter installed in a commercial vehicle Any Power Inverter whose serial number has been defaced altered or removed Any consequential damages arising from the loss of use of the product including but no...