background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

Modbus TCP Slave / KNX

 

 

Document code: MN67815_ENG     Revision 1.100   Pagina 1 di 24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.100 
English 

 

Modbus TCP Slave / KNX - Converter 

 (Order Code:  HD67815-KNX-B2) 

 
for Website information:  

www.adfweb.com?Product=HD67815

  

 

for Price information: 

www.adfweb.com?Price=HD67815-KNX-B2

  

 
 

Benefits and Main Features: 

 

Very easy to configure 

 

Electrical isolation 

 

Temperature range: -40°C/85°C (-40°F/185°F) 

 

For others KNX products, see also the following links: 

 

Converter KNX to  

www.adfweb.com?Product=HD67801

      

(BACnet Master)

 

www.adfweb.com?Product=HD67802

      

(BACnet Slave) 

www.adfweb.com?Product=HD67803

       

(CAN) 

www.adfweb.com?Product=HD67804

      

(CANopen) 

www.adfweb.com?Product=HD67807

      

(EtherNet/IP) 

www.adfweb.com?Product=HD67808

      

(DeviceNet Master) 

www.adfweb.com?Product=HD67809

      

(DeviceNet Slave) 

www.adfweb.com?Product=HD67810

      

(J1939) 

www.adfweb.com?Product=HD67811

       

(M-Bus Master/wM-Bus) 

www.adfweb.com?Product=HD67812

      

(Modbus Master) 

www.adfweb.com?Product=HD67813

       

(Modbus Slave) 

www.adfweb.com?Product=HD67814

       

(Modbus TCP Master)

 

www.adfweb.com?Product=HD67818

       

(PROFINET Slave) 

www.adfweb.com?Product=HD67820

       

(SNMP) 

www.adfweb.com?Product=HD67821

       

(DMX) 

 

 

Do you have an your customer protocol? 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? do you want help? 

www.adfweb.com?Cmd=helpme

 

 

User Manual   

 

Summary of Contents for HD67815-KNX-B2

Page 1: ...web com Product HD67801 BACnet Master www adfweb com Product HD67802 BACnet Slave www adfweb com Product HD67803 CAN www adfweb com Product HD67804 CANopen www adfweb com Product HD67807 EtherNet IP w...

Page 2: ...UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most r...

Page 3: ...ks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation asse...

Page 4: ...Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Modbus TCP Slave KNX Document code MN67815_ENG Revision 1 100 Pagina 4 di 24 EXAMPLE OF...

Page 5: ...Fweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Modbus TCP Slave KNX Document code MN67815_ENG Revision 1 100 Pagina 5 di 24 CONNECTION SCHEME Figure 1 Conne...

Page 6: ...p to 1440 bytes in reading and 1440 bytes in writing Triple isolation between KNX Power Supply KNX Ethernet Power Supply Ethernet Two directional information between KNX bus and Modbus TCP bus Mountab...

Page 7: ...lave KNX Document code MN67815_ENG Revision 1 100 Pagina 7 di 24 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax...

Page 8: ...t two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip...

Page 9: ...de 1 Device State green Blinks slowly 1Hz ON Device powered OFF Device not powered 2 KNX communication yellow Blinks when KNX frame is received 3 Modbus communication yellow Blinks when Modbus TCP fra...

Page 10: ...lighting to control dampers to the security to the heating monitoring to the conditioning to the hydric control and alarms to energy management and so on Characteristics Description TP1 256 Medium Shi...

Page 11: ...CP communication and for programming the device The Ethernet connection must be made using Connector2 of HD67815 KNX B2 with at least a Category 5E cable The maximum length of the cable should not exc...

Page 12: ...the available software that runs with Windows called SW67815 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last versio...

Page 13: ...contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a Programmable Modbus TCP Slave KNX Converter in order to configure...

Page 14: ...re is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Con...

Page 15: ...eld ID Device the ID of the KNX side of the converter is defined The means of the fields for the Modbus TCP Slave section are In the fields IP ADDRESS the IP address that you want to give to the Conve...

Page 16: ...Source Address the Source Address to assign to the KNX message is defined In the field Dest Group the Group address 2 level structure 3 level structure or free address structure or the device address...

Page 17: ...value If the field On Timer is checked the gateway sends the KNX command cyclically In the field Poll Time the delay in ms between two KNX commands is defined if On Timer is checked In the field Posit...

Page 18: ...ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK...

Page 19: ...ings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 or 11 make sure that you have the administrator privileg...

Page 20: ...ined in the section Set Communication Each bit will represent the status of a KNX request If the converter receives a correct message before the timeout the status bit is put to 0 If the converter doe...

Page 21: ...Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Modbus TCP Slave KNX Document code MN67815_ENG Revision 1 100 Pagina 21 di 24 MECHANICAL DIMENSIONS Figure 7 Mechanic...

Page 22: ...part number is formed by a valid combination of the following HD67815 KNX B 2 Connectors Type 2 Fixed 5mm Screw Terminal Enclosure Type B 4M 35mm DIN Rail mounting Device Family HD67815 KNX Modbus TC...

Page 23: ...countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicab...

Page 24: ...o exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about...

Reviews: