![Freescale Semiconductor MC9S12ZVM series Reference Manual Download Page 77](http://html1.mh-extra.com/html/freescale-semiconductor/mc9s12zvm-series/mc9s12zvm-series_reference-manual_2330602077.webp)
Chapter 1 Device Overview MC9S12ZVM-Family
MC9S12ZVM Family Reference Manual Rev. 1.3
Freescale Semiconductor
77
1.13.6.3
Dead time Distortion Correction
PMSM motor control applications driven by sinusoidal voltages by default require zero crossing
information of phase currents to determine the point in time to change sign of deadtime compensation
value to be added to duty cycles.
The GDU phase comparator signals are connected internally to the PMF ISx inputs. This allows the dead
time distortion correction to be applied directly based on the phase status.
1. Align rotor to stator field.
2. Await phase comparator status change.
3. Switch to alternate duty cycle register to compensate distortion.