Chapter 13 Programmable Trigger Unit (PTUV2)
MC9S12ZVM Family Reference Manual Rev. 1.3
Freescale Semiconductor
468
Table 13-8. PTUIFL Register Field Descriptions
Field
Description
7
TG1AEIF
Trigger Generator 1 Memory Access Error Interrupt Flag — This bit is set if trigger generator 1 uses a read
address outside the memory address range, see the MMC section for the supported memory area.
0 No trigger generator 1 memory access error occurs
1 Trigger generator 1 memory access error occurs
6
TG1REIF
Trigger Generator 1 Reload Error Interrupt Flag — This bit is set if a new reload event occurs when the
trigger generator has neither reached the end of list symbol nor the maximum possible triggers. This bit is not
set if the reload event was forced by an asynchronous commutation event.
0 No trigger generator 1 reload error occurs
1 Trigger generator 1 reload error occurs
5
TG1TEIF
Trigger Generator 1 Timing Error Interrupt Flag — This bit is set if the trigger generator receives a time value
which is below the current counter value.
0 No trigger generator 1 error occurs
1 Trigger generator 1 error occurs
4
TG1DIF
Trigger Generator 1 Done Interrupt Flag —This bit is set if the trigger generator receives the end of list symbol
or the maximum number of generated trigger events was reached.
0 Trigger generator 1 is running
1 Trigger generator 1 is done
3
TG0AEIF
Trigger Generator 0 Memory Access Error Interrupt Flag — This bit is set if trigger generator 0 uses a read
address outside the memory address range, see the MMC section for the supported memory area.
0 No trigger generator 0 memory access error occurred
1 Trigger generator 0 memory access error occurred
2
TG0REIF
Trigger Generator 0 Reload Error Interrupt Flag — This bit is set if a new reload event occurs when the
trigger generator has neither reached the end of list symbol nor the maximum possible triggers. This bit is not
set if the reload event was forced by an asynchronous commutation event.
0 No trigger generator 0 reload error occurs
1 Trigger generator 0 reload error occurs
1
TG0TEIF
Trigger Generator 0 Timing Error Interrupt Flag — This bit is set if the trigger generator receives a time value
which is below the current counter value.
0 No trigger generator 0 error occurs
1 Trigger generator 0 error occurs
0
TG0DIF
Trigger Generator 0 Done Interrupt Flag —This bit is set if the trigger generator receives the end of list symbol
or the maximum number of generated trigger events was reached.
0 Trigger generator 0 is running
1 Trigger generator 0 is done