![Freescale Semiconductor MC9S12ZVM series Reference Manual Download Page 747](http://html1.mh-extra.com/html/freescale-semiconductor/mc9s12zvm-series/mc9s12zvm-series_reference-manual_2330602747.webp)
Appendix A MCU Electrical Specifications
MC9S12ZVM Family Reference Manual Rev. 1.3
Freescale Semiconductor
747
A.1.7
Operating Conditions
This section describes the operating conditions of the device. Unless otherwise noted these conditions
apply to the following electrical parameters.
NOTE
Please refer to the temperature rating of the device with regards to the
ambient temperature T
A
and the junction temperature T
J
. For power
dissipation calculations refer to
Section A.1.8, “Power Dissipation and
.
NOTE
Operation is guaranteed when powering down until low voltage reset
assertion.
Table A-6. Operating Conditions
Num
Rating
Symbol
Min
Typ
Max
Unit
1
Voltage regulator and LINPHY supply voltage
(1)
1. Normal operating range is 5.5 V - 18 V. Continuous operation at 40 V is not allowed. Only Transient Conditions (Load Dump)
single pulse t
max
<400 ms. Operation down to 3.5V is guaranteed without reset, however some electrical parameters are
specified only in the range above 4.5 V.
V
SUP
3.5
12
40
V
2
Voltage difference V
DDX
to V
DDA
∆
VDDX
–0.1
—
0.1
V
3
Voltage difference V
SSX
to V
SSA
∆
VSSX
–0.1
—
0.1
V
4
Oscillator
f
osc
4
—
16
MHz
5
Bus frequency
(2)
-40
°
C < T
j
< 150
°
C
150
°
C < T
j
< 175
°
C (Temp option W only)
2. The flash program and erase operations must configure f
NVMOP
as specified in the NVM electrical section.
f
bus
(4)
4. Refer to f
ATDCLK
for minimum ADC operating frequency. This is derived from the bus clock.
—
—
50
40
MHz
6
Bus frequency without flash wait states
-40
°
C < T
j
< 150
°
C
150
°
C < T
j
< 175
°
C (Temp option W only)
f
WSTAT
—
—
25
20
MHz
7a
Operating junction temperature range
Operating ambient temperature range
(3)
(option V)
3. Please refer to
Section A.1.8, “Power Dissipation and Thermal Characteristics”
for more details about the relation between
ambient temperature T
A
and device junction temperature T
J
.
T
J
T
A
–40
–40
—
—
125
105
°
C
7b
Operating junction temperature range
Operating ambient temperature range
(option M)
T
J
T
A
–40
–40
—
—
150
125
°
C
7c
Operating junction temperature range
Operating ambient temperature range
(option W)
T
J
T
A
–40
–40
—
—
175
150
°
C