8
8
8-148
8-148
Service Mode > COPIER > OPTION > FNC-SW
Service Mode > COPIER > OPTION > FNC-SW
OPTION
■
FNC-SW
COPIER > OPTION > FNC-SW
MODEL-SZ
Fixed magnifictn & DADF orgnl dtct size
Lv.1 Details
To set the fixed magnification ratio display and the original detection
size with DADF.
It is set automatically at the time of installation of the Reader according
to the location.
Use case
Upon user’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 3
0: AB configuration (6R5E) for Japan, 1: Inch configuration (5R4E) for
North/Middle/South America, 2: A configuration (3R3E) for Europe, 3:
AB/Inch configuration (6R5E) for Asia, Oceania, South America
Default value
The value differs according to the location.
SCANSLCT
ON/OFF of scan area calculate function
Lv.2 Details
To set ON/OFF of the function to calculate scanning area from the
specified paper size.
When the paper size is larger than the original size, selecting ON
reduces productivity because the scanning area gets larger.
Use case
When matching the scanning area with the paper size
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: OFF (calculated from the detected original size)
1: ON (calculated from the specified paper size)
Default value
0
COPIER > OPTION > FNC-SW
DH-SW
ON/OFF of auto adjustment (D-half/D-max)
Lv.2 Details
To set ON/OFF of auto adjustment (D-half/D-max control).
D-half/D-max control that is set to OFF is not executed at warm-up
rotation/last rotation.
The execution interval can be set by DH-TMG (at warm-up rotation)
and INTROT-2 (at last rotation).
Use case
- When D-half/D-max-related failure occurs/when identifying the cause
of D-half-related failure
- Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Be sure to set the value back to 1 after servicing.
Display/adj/set range
0 to 2
0: D-half OFF, D-max ON
1: D-half ON, D-max ON
2: D-half OFF, D-max OFF
Default value
1
Related service mode COPIER> OPTION> IMG-FIX> DH-TMG
COPIER> OPTION> FNC-SW> INTROT-2
SENS-CNF
Setting of original detection size
Lv.2 Details
To set original detection size according to AB configuration/Inch
configuration/A configuration.
When replacing the Reader Controller PCB/clearing RAM data, the
value becomes 0. Set 1 for Inch configuration/A configuration machine.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: AB configuration, 1: Inch configuration
Default value
The value differs according to the location.