2
2
2-267
2-267
Technology > DCM > DCM > Import/export by service mode (internal)
Technology > DCM > DCM > Import/export by service mode (internal)
■
Import/export by service mode (internal)
When selecting the HDD of the machine at execution of BACKUP from the top screen
of service mode, service mode settings can be saved. Setting values of Main Controller
2, Reader Controller, DC Controller, etc. can be collectively saved. It can be used when
recovering the initial status after having tried multiple setting changes temporarily for
troubleshooting, etc.
Note:
DCM must not be used when replacing a PCB.
Be sure to use a method such as backup of SRAM of the Main Controller 2/service
mode backup of DCON/RCON.
DCM enables to back up only service mode setting values. There is still necessary
information other than setting values when replacing a PCB.
SRAM backup or service mode backup enables to save data other than setting values.
●
Export
Preparation
There is no need to newly prepare for saving data to the HDD of the machine.
Overall flow
Here is a procedure for exporting data of the HDD of the machine.
Procedure
1. Select internal HDD as save destination (LIST=2)
2. Register password
3. Import from the internal HDD
Procedure for backing up data to the HDD of the machine
1. Select LIST after the screen moves to <BACKUP>.
F-2-470
2. Select LIST after the screen moves to <BACKUP>.
3. When saving to the internal HDD, select 2 and press OK.
4. The names of .dcm files saved in the internal HDD are displayed.
F-2-471
F-2-472