4
4
4-124
4-124
Parts Replacement and Cleaning > Image Formation System > Removing the Secondary Transfer Inner Roller > Actions after Replacement
Parts Replacement and Cleaning > Image Formation System > Removing the Secondary Transfer Inner Roller > Actions after Replacement
5) Remove the Secondary Transfer Inner Roller.
6) Apply 1 rice-grain sized grease (FY9-6006: Super Lube) to the edge of
the Secondary Transfer Inner Roller.
F-4-163
F-4-164
F-4-165
CAUTION:
Be careful of the installation direction when installing the Secondary Transfer Inner
Roller.
■
Actions after Replacement
1) Turn ON the power of the host machine.
2) When the machine is in standby condition, Execute the following in user mode: (Settings/
Registration > Adjustment/Maintenance > Adjust Image Quality > Auto Adjust Gradation).
3) Execute the ITB equilibrium position detection in service mode.
COPIER>FUNCTION>MISC-P>ITB-INIT
This service mode will take approx. 3 to 6 minutes (for iR-ADV C5255/C5250) or approx. 4 to
8 minutes (for iR-ADV C5240/C5235).
4) After executing the above, check that the values of COPIER>DISPLAY>MISC>ITB-POS
and ITB-POS2 are within the range from -350 to 350.