Technology > MEAP > Option for exclusive individual measure > Error at starting up the MEAP application/Setting to hide JAM screen (level 2)
Technology > MEAP > Option for exclusive individual measure > Error at starting up the MEAP application/Setting to hide JAM screen (level 2)
4) Press either 0 (hide) or 1 (display) on control panel (the numerical value input in the field is
displayed), and press [OK] button.
5) Check to see that it is reflected in setting field, and restart the device.
F-2-368
■
Error at starting up the MEAP application/Setting to hide JAM
screen (level 2)
In the case that operation is restricted by MEAP application, hide the warning screen of error/
JAM (such as JAM screen, door opening, no-toner). In the case that these errors occur, there
will be a display indicating 'call the service personnel' etc.
Note:
Part of the warning screens is displayed if shifting to the device screen.
• As for the screens for jam and no-toner, the warning screen (animation) can be displayed
by pressing the followings: [Device Screen] > [Recovery Procedure]
• As for the screen for door opening, the warning screen cannot be displayed because
there is no display for [[Device Screen] > [Recovery Procedure]
Default value
1: No activation of warning display
Setting range, item
0: display warning screen 1: hide warning screen
●
Setting Procedure
1) Start [SERVICE MODE] in Level 1.
2) Press [COPIER] > [Option] > [DSPLY-SW] buttons.
F-2-369