8
8
8-46
8-46
Service Mode > COPIER > DISPLAY > HT-C
Service Mode > COPIER > DISPLAY > HT-C
■
HT-C
COPIER > DISPLAY > HT-C
TGT-A-Y
Dis of ARCDAT screen A Y-color target VL
Lv.2 Details
To display the Y-patch target value of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-A-M
Dis of ARCDAT screen A M-color target VL
Lv.2 Details
To display the M-patch target value of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-A-C
Dis of ARCDAT screen A C-color target VL
Lv.2 Details
To display the C-patch target value of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-A-K
Dis of ARCDAT screen A Bk-clr target VL
Lv.2 Details
To display the Bk-patch target value of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-B-Y
Dis of ARCDAT screen B Y-color target VL
Lv.2 Details
To display the Y-patch target value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
COPIER > DISPLAY > HT-C
TGT-B-M
Dis of ARCDAT screen B M-color target VL
Lv.2 Details
To display the M-patch target value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-B-C
Dis of ARCDAT screen B C-color target VL
Lv.2 Details
To display the C-patch target value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-B-K
Dis of ARCDAT screen B Bk-clr target VL
Lv.2 Details
To display the Bk-patch target value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-C-Y
Dis of ARCDAT screen C Y-color target VL
Lv.2 Details
To display the Y-patch target value of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-C-M
Dis of ARCDAT screen C M-color target VL
Lv.2 Details
To display the M-patch target value of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700