8
8
8-234
8-234
Service Mode > COPIER > COUNTER > DRBL-2
Service Mode > COPIER > COUNTER > DRBL-2
COPIER > COUNTER > DRBL-2
PD-FD-RL
Feed Roller parts counter: Deck
Lv.1 Details
Feed Roller of Paper Deck/POD Deck Lite/Multi Deck (Upper)
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
C3-SP-RL
Cassette3 Separation Roller prts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
C3-FD-RL
Cassette3 Feed Roller parts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
C4-SP-RL
Cassette4 Separation Roller prts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
COPIER > COUNTER > DRBL-2
C4-FD-RL
Cassette4 Feed Roller parts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
FIN-STPR
Stapler parts counter: Fin-A1/C1
Lv.1 Details
Stapler Unit
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of times
Default value
0
SDL-STPL
Saddle Stapler parts counter: Fin-C1
Lv.1 Details
Saddle Stapler Unit
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of times
Default value
0
FN-BFFRL
Buffer Roller parts counter: Fin-C1
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0