9
9
9-238
9-238
Installation > [TYPE-6] > Installation Procedure > Removing the Signal Cable and Power Supply Cable
Installation > [TYPE-6] > Installation Procedure > Removing the Signal Cable and Power Supply Cable
Use 2 of them
Use 6 of them
[24] Wire saddle (Middle)
X 1
[22] Wire saddle (Small) X 5
[21] Edge Saddle X 1
[20] Screw (TP; M3x6) X 10
[17] LED Label (Small) X 1
[18] LED Label (large) X 1
[19] HDD Connection Plate
X 1
[25] Ring Core X 1
[23] Wire saddle (large) X 1
[16] LED Board (large) X 1
FK2-8324 or A: LED
<CD/Guides>
• HDD Data Encryption & Mirroring Kit-C1 User Documentation
• HDD Data Encryption Kit Notice
• Installation Procedure
• Noticed for FCC/IC
F-9-630
Setting Before Turning OFF the Power
CAUTION:
Be sure to turn OFF the main power after executing this service mode setting.
Turning OFF the main power without executing service mode causes "E602-5001
(procedure error before installing the HDD Encryption Board)" to occur when turning
ON the main power after installing the Encryption Board.
When this error occurs, the machine needs to be returned again to the initial state in
which no Encryption Board is installed.
1) Execute the following service mode (level 1).
• COPIER > FUNCTION > INSTALL > HD-CRYP
Check Items when Turning OFF the Main Power
Check that the main power switch is OFF.
1) Turning off the Main Power Supply Switch of the Host Machine.
2) Check that the display on the Control Panel and the Main Power Supply Lamp are turned
off before disconnecting the outlet.
Installation Procedure
■
Removing the Signal Cable and Power Supply Cable
1) Open the Right Lower Cover. (Open the Right Upper Cover simultaneously.)
F-9-631