Parts Replacement and Cleaning > Image Formation System > Removing the ITB Unit > Procedure
Parts Replacement and Cleaning > Image Formation System > Removing the ITB Unit > Procedure
CAUTION:
When pulling out the ITB Unit, be sure not to lower the ITB Pressure Release Lever
below the position where clicky sense is felt. If the ITB Unit is pulled out while the lever
is lowered, the ITB is scraped by the Plate and this may cause to make scratches on
the ITB surface.
Click position
Not to lower the ITB Pressure Releace Lever
below the position where clicky sense is felt.
ITB pressure
release lever
When pulling out the ITB Unit, it may drop because it does not click at stop position if
pulled out while lifting it. Thus, be careful of pulling it out.
4) Pull out the ITB Unit up to the stop label position flatly.
• 2 screws
Stop label position
x2
5) Hold the ITB Unit as show in the below figure, and remove in the direction of the arrow.
F-4-126
F-4-127