Service Mode > COPIER > FUNCTION > INSTALL
Service Mode > COPIER > FUNCTION > INSTALL
COPIER(1)>FUNCTION(4)>INSTALL(1)(list:29)
CNT-DATE
Set counter send start date to SC server
Lv.1 Details
To set the year, month, date, hour and minute to send counter
information to the sales company's server.
This is displayed only when the Embedded-RDS third-party extended
function is available.
Use case
When the Embedded-RDS third-party expanded function is available
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
YYYYMMDDHHMM (12 digits)
YYYY: Year, MM: Month, DD: Date, HH: Hour, MM: Minute
Default value
000000000000
CNT-INTV
Set counter send interval to SC server
Lv.1 Details
To set the interval of sending counter information to the sales
company's server in a unit of one hour.
This is displayed only when the Embedded-RDS third-party extended
function is available.
Use case
- When restarting potential control after execution of COPIER>
OPTION> IMG-FIX> PO-CNT
- When the D-max control condition is changed
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
1 to 168 (=1 week)
Unit
hour
Default value
24
COPIER(1)>FUNCTION(4)>INSTALL(1)(list:29)
INISET-4
All color Dev Ass'y initial instal mode
Lv.1 Details
To automatically execute operation necessary for initial installation of
the Developing Assemblies of all colors.
1. Idle rotation of the Developing Assembly
2. Initialization of the Toner Density Sensor
3. Secondary transfer ATVC control
4. Patch light intensity correction
5. Background correction
6. Discharge current control
7. Primary transfer ATVC control
8. Initialization of the Patch Sensor
9. Auto registration
10. D-max control
11. D-half control
12. ARCDAT-Lite (creation of target)
13. Cleaning of the Secondary Transfer Roller twice
14. Counter reset of the Developing Assembly
Use case
- At installation
- When replacing the Developing Assemblies of all colors
Adj/set/operate method Select the item, and then press OK key.
Caution
- Use this item only when replacing Developing Assemblies of 4 colors
simultaneously.
Display/adj/set range
During operation: xxx second (remaining time), At normal termination:
OK, At abnormal termination: NG
Required time
155 sec
Related service mode COPIER> FUNCTION> INSTALL> INISET-Y, INISET-M, INISET-C,
INISET-K