Technology > Embedded RDS > E-RDS Setup > Steps to Service Call button settings
Technology > Embedded RDS > E-RDS Setup > Steps to Service Call button settings
If the communication is successful, "OK!" is displayed. If "NG!" (failed) appears, refer to the
"Troubleshooting" and repeat until "OK!" is displayed.
NOTE:
The communication results with UGW can be distinguished by referring to the COM-
LOG. By performing the communication test with UGW, E-RDS acquires schedule
information and starts monitoring and meter reads operation.
F-2-379
■
Steps to Service Call button settings
●
Steps for settings to display the service call button
In the case of supporting a service by the service call button, follow the instructions described
below to display the service call button.
1. Start [Service Mode] at Level 1.
2. Select [COPIER] > [Option] > [USER] > [SCALL-SW].
3. Touch the numeric button [1] on the control panel (the setting value is changed to 1) and
touch the [OK] button. (The data is reflected to the setting value field.)
F-2-380
F-2-381