4
4
4-81
4-81
Parts Replacement and Cleaning > Main Controller > Removing the HDD > Procedure
Parts Replacement and Cleaning > Main Controller > Removing the HDD > Procedure
Main Controller
Removing the HDD
■
Actions before Replacement
Backup the Settings/Registration data.
1) Select the following so that the service mode setting values can be exported on remote UI.
Service mode (Lv1) > Option > USER > SMD-EXPT > [1]
2) Execute the collective export on remote UI.
Settings/Registration > Management Settings > Data Management > Import/Export All >
Export
Select "Select All", and enter the encryption password. Execute "Start Exporting" to create
a backup file (DCM file).
CAUTION:
Collective export cannot be executed in the following cases.
• Job is being executed, or job is being waited for (various functions set by
transmission, forwarding, fax reception, I-FAX reception, report print and timer)
• Individual import/export is being executed
• The address book is being remotely referenced by another imageRUNNER
ADVANCE
• Device information is being distributed
• An error has occurred
• Box is being backed up
■
Procedure
1) Open the Right Lower Cover and Right Upper Cover.
2) Remove the Right Rear Cover.
• 1 screw (RS tight; M4)
• 2 screws (TP; M3)
• 1 claw
Claw
x3
3) Open the HDD Lid.
• 1 screw
F-4-50
F-4-51