8
8
8-48
8-48
Service Mode > COPIER > DISPLAY > HT-C
Service Mode > COPIER > DISPLAY > HT-C
COPIER > DISPLAY > HT-C
SUM-C-Y
Dis ARCDAT screen C Y-color ctrl differ
Lv.2 Details
To display Y-patch control difference of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SUM-C-M
Dis ARCDAT screen C M-color ctrl differ
Lv.2 Details
To display M-patch control difference of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SUM-C-C
Dis ARCDAT screen C C-color ctrl differ
Lv.2 Details
To display C-patch control difference of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SUM-C-K
Dis ARCDAT screen C Bk-color ctrl differ
Lv.2 Details
To display Bk-patch control difference of screen C in ARCDAT
control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SGNL-A-Y
Dis ARCDAT screen A Y-patch current VL
Lv.2 Details
To display the current Y-patch value of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGNL-A-M
Dis ARCDAT screen A M-patch current VL
Lv.2 Details
To display the current M-patch value of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
COPIER > DISPLAY > HT-C
SGNL-A-C
Dis ARCDAT screen A C-patch current VL
Lv.2 Details
To display the current C-patch value of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGNL-A-K
Dis ARCDAT screen A Bk-patch current VL
Lv.2 Details
To display the current Bk-patch value of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGNL-B-Y
Dis ARCDAT screen B Y-patch current VL
Lv.2 Details
To display the current Y-patch value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGNL-B-M
Dis ARCDAT screen B M-patch current VL
Lv.2 Details
To display the current M-patch value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGNL-B-C
Dis ARCDAT screen B C-patch current VL
Lv.2 Details
To display the current C-patch value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGNL-B-K
Dis ARCDAT screen B Bk-patch current VL
Lv.2 Details
To display the current Bk-patch value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGNL-C-Y
Dis ARCDAT screen C Y-patch current VL
Lv.2 Details
To display the current Y-patch value of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023