7) Hold the ITB Unit as show in the below figure, and remove in the direction of the arrow.
CAUTION:
When installing the ITB Unit, align the ITB Unit with the 2 positions at the lead edge of
rail.
ITB unit
Rails
F-4-104
●
Removing the Process Unit
CAUTION:
When installing/removing the Process Unit, do not remove the Waste Toner Container.
F-4-103
8) Pull out the Process Unit until it stops.
• 2 screws
x2
9) Remove the 4 stepped screws fixed on the right and left rails.
x4
10) Hold the front and rear of Process Unit and remove it flatly.