Service Mode > COPIER > ADJUST > CCD
Service Mode > COPIER > ADJUST > CCD
COPIER > ADJUST > CCD
DFCH2G10
Complex chart No.10 data(G) [Front side]
Lv.1 Details
To derive the front/back side linearity, set the Green data (for paper
front) of No.10 image in DADF complex chart.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 2550
Default value
0
CCD-CHNG
Scanner Unit(ppr frt) rplce flag setting
Lv.1 Details
To set the calculation mode of MTF filter coefficient that is used at
the replacement of Scanner Unit (paper front).
When replacing the Scanner Unit (paper front), enter 1. When
replacing the Reader Controller PCB/clearing RAM data, enter the
value of service label.
Use case
- When replacing the Scanner Unit (paper front)
- When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Data at factory shipment is used.
1: Data at factory shipment is not used. (Scanner Unit (paper front) is
already replaced.)
Default value
0
MTF-M1
MTF value 1 setting: horz scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
- When replacing the Scanner Unit
- When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 80
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-M2
MTF value 2 setting: horz scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
- When replacing the Scanner Unit
- When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 80
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
COPIER > ADJUST > CCD
MTF-M3
MTF value 3 setting: horz scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
- When replacing the Scanner Unit
- When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 80
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-M4
MTF value 4 setting: horz scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
- When replacing the Scanner Unit
- When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 80
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-M5
MTF value 5 setting: horz scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
- When replacing the Scanner Unit
- When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 80
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-M6
MTF value 6 setting: horz scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
- When replacing the Scanner Unit
- When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 80
Default value
50
Related service mode