7
7
7-93
7-93
Error•Jam•Alarm > Error Code > Error Code Details
Error•Jam•Alarm > Error Code > Error Code Details
E
code
Detailed
code
Occurance
area
Items
Description
E747 C51A
00
Title
Error in Main Controller PCB2
Description Error in Main Controller PCB2
Remedy
1. Check contact of ScanI/F cable. Check contact of the
Bypass PCB or Open I/F PCB. Check contact of SDRAM
at Main Controller PCB2.
2. Replace the Bypass PCB or Open I/F PCB
3. Replace the SDRAM at Main Controller PCB2
4. Replace the Main Controller PCB2
5. Replace the HDD (replace the new encryption board)
E747 C51B
00
Title
Error in Main Controller PCB2
Description Error in Main Controller PCB2
Remedy
1. Check contact of ScanI/F cable. Check contact of the
Bypass PCB or Open I/F PCB. Check contact of SDRAM
at Main Controller PCB2.
2. Replace the Bypass PCB or Open I/F PCB
3. Replace the SDRAM at Main Controller PCB2
4. Replace the Main Controller PCB2
5. Replace the HDD (replace the new encryption board)
E747 C51C
00
Title
Error in Main Controller PCB2
Description Error in Main Controller PCB2
Remedy
1. Check contact of ScanI/F cable. Check contact of the
Bypass PCB or Open I/F PCB. Check contact of SDRAM
at Main Controller PCB2.
2. Replace the Bypass PCB or Open I/F PCB
3. Replace the SDRAM at Main Controller PCB2
4. Replace the Main Controller PCB2
5. Replace the HDD (replace the new encryption board)
E747 C51D
00
Title
Error in Main Controller PCB2
Description Error in Main Controller PCB2
Remedy
1. Check contact of ScanI/F cable. Check contact of the
Bypass PCB or Open I/F PCB. Check contact of SDRAM
at Main Controller PCB2.
2. Replace the Bypass PCB or Open I/F PCB
3. Replace the SDRAM at Main Controller PCB2
4. Replace the Main Controller PCB2
5. Replace the HDD (replace the new encryption board)
E747 C51F
00
Title
Error in Main Controller PCB2
Description Error in Main Controller PCB2
Remedy
1. Check contact of ScanI/F cable. Check contact of the
Bypass PCB or Open I/F PCB. Check contact of SDRAM
at Main Controller PCB2.
2. Replace the Bypass PCB or Open I/F PCB
3. Replace the SDRAM at Main Controller PCB2
4. Replace the Main Controller PCB2
5. Replace the HDD (replace the new encryption board)
E
code
Detailed
code
Occurance
area
Items
Description
E747 C701
00
Title
Error in Main Controller PCB2
Description Error in Main Controller PCB2
Remedy
1. Check contact of ScanI/F cable. Check contact of the
Bypass PCB or Open I/F PCB. Check contact of SDRAM
at Main Controller PCB2.
2. Replace the Bypass PCB or Open I/F PCB
3. Replace the SDRAM at Main Controller PCB2
4. Replace the Main Controller PCB2
5. Replace the HDD (replace the new encryption board)
E747 C706
00
Title
Error in Main Controller PCB2
Description Error in Main Controller PCB2
Remedy
1. Check contact of ScanI/F cable. Check contact of the
Bypass PCB or Open I/F PCB. Check contact of SDRAM
at Main Controller PCB2.
2. Replace the Bypass PCB or Open I/F PCB
3. Replace the SDRAM at Main Controller PCB2
4. Replace the Main Controller PCB2
5. Replace the HDD (replace the new encryption board)
E747 DC00
00
Title
Error in Main Controller PCB2
Description Error in Main Controller PCB2
Remedy
1. Check contact of ScanI/F cable. Check contact of the
Bypass PCB or Open I/F PCB. Check contact of SDRAM
at Main Controller PCB2.
2. Replace the Bypass PCB or Open I/F PCB
3. Replace the SDRAM at Main Controller PCB2
4. Replace the Main Controller PCB2
5. Replace the HDD (replace the new encryption board)
E747 DF00
00
Title
Undetected error of Image Process Chip S
Description Undetected error of Image Process Chip S
Remedy
Check contact of ScanI/F cable --> Replace
-> Replace the Main Controller PCB 2
E747 FF00
00
Title
A wrong Sub Board was detected
Description A wrong Sub Board was detected
Remedy
Check contact of ScanI/F cable --> Replace
Check contact of the Sub Board O and the cable -->
Replace
Replace the Main Controller PCB 2
E747 FF01
00
Title
Connection failure with DDR-SDRAM (P)/inappropriate
memory size
Description Connection failure with DDR-SDRAM (P)/inappropriate
memory size
Remedy
Replace the DDR-SDRAM (P)
E748 2010
00
Title
Error in Flash PCB
Description Unable to find the IPL (startup program).
Remedy
Contact to the sales companies.