9
9
9-74
9-74
Installation > Utility Tray-A2 > Installation Procedure
Installation > Utility Tray-A2 > Installation Procedure
Installation Procedure
1) Remove packing tapes.
2) Loosen the 2 screws, and move the Utility Tray Mounting Plate in the direction of the arrow
until it stops.
Utility Tray Mounting Plate
3) While pulling the [A] part of the Utility Tray, remove the Utility Tray Mounting Plate.
CAUTION:
To avoid damage, do not pull the [A] part of the Utility Tray too much.
[A]
F-9-180
F-9-181
4) Remove the 5 Face Seals. (Removed Face Seal will not be used.)
Face Seal
5) Install the Utility Tray Mounting Plate.
• 5 screws (TP; M4x8 Black)
CAUTION: Points to Note at Installation
If the holes are marked as shown below, align the holes marked with D, G, J, M and P
with the holes in the host machine.
A
Q R
S
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
F-9-183
x5
F-9-182
F-9-184