Error•Jam•Alarm > Error Code > Error Code Details
Error•Jam•Alarm > Error Code > Error Code Details
E
code
Detailed
code
Occurance
area
Items
Description
E197 0080
05
Title
Timeout error in EHOB transmission-waiting
Description Communication failure between the DC Controller PCB
(UN1) and Laser Scanner Unit.
Remedy
1. Turn OFF and then ON the power.
2. Check connection of harness on the target color side
(YM/CK).
3. Replace the DC Controller PCB (UN1).
4. Replace the Laser Scanner Unit.
5. Replace the harness on the target color side (YM/CK).
E197 0081
05
Title
Timeout error in EHOB reception-waiting
Description Communication failure between the DC Controller PCB
(UN1) and Laser Scanner Unit.
Remedy
1. Turn OFF and then ON the power.
2. Check connection of harness on the target color side
(YM/CK).
3. Replace the DC Controller PCB (UN1).
4. Replace the Laser Scanner Unit.
5. Replace the harness on the target color side (YM/CK).
E197 00A0
05
Title
Timeout error in HOB transmission-waiting
Description Communication failure between CPU and LSI on the DC
Controller PCB (UN1).
Remedy
1. Turn OFF and then ON the power.
2. Replace the DC Controller PCB (UN1).
E197 00B0
05
Title
Timeout error in HOB reception-waiting
Description Communication failure between CPU and LSI on the DC
Controller PCB (UN1).
Remedy
1. Turn OFF and then ON the power.
2. Replace the DC Controller PCB (UN1).
E197 00E0
05
Title
Timeout error in the Motor stop signal interruption
reception
Description Communication error between CPU and LSI on the DC
Controller PCB
Remedy
1. Turn OFF and then ON the power.
2. Replace the DC Controller PCB (UN1).
E197 0100
05
Title
Error in communication of HOB DMA mode
Description Communication failure between CPU and LSI on the DC
Controller.
Remedy
1. Turn OFF and then ON the power.
2. Replace the DC Controller PCB (UN1).
E197 0101
05
Title
Error in communication of HOB single-shot mode
Description Communication failure between CPU and LSI on the DC
Controller PCB (UN1).
Remedy
1. Turn OFF and then ON the power.
2. Replace the DC Controller PCB (UN1).
E
code
Detailed
code
Occurance
area
Items
Description
E197 0102
05
Title
Error in communication of HOB single-shot mode
Description Communication failure between CPU and LSI on the DC
Controller PCB (UN1).
Remedy
1. Turn OFF and then ON the power.
2. Replace the DC Controller PCB (UN1).
E197 0103
05
Title
Timeout error in HOB single-shot mode
Description Communication failure between CPU and LSI on the DC
Controller PCB (UN1).
Remedy
1. Turn OFF and then ON the power.
2. Replace the DC Controller PCB (UN1).
E197 0180
05
Title
Timeout error in EHOB transmission-waiting
Description Communication failure between the DC Controller PCB
(UN1) and Laser Scanner Unit.
Remedy
1. Turn OFF and then ON the power.
2. Check connection of harness on the target color side
(YM/CK).
3. Replace the DC Controller PCB (UN1).
4. Replace the Laser Scanner Unit.
5. Replace the harness on the target color side (YM/CK).
E197 0181
05
Title
Timeout error in EHOB reception-waiting
Description Communication failure between the DC Controller PCB
(UN1) and Laser Scanner Unit.
Remedy
1. Turn OFF and then ON the power.
2. Check connection of harness on the target color side
(YM/CK).
3. Replace the DC Controller PCB (UN1).
4. Replace the Laser Scanner Unit.
5. Replace the harness on the target color side (YM/CK).
E197 01A0
05
Title
Timeout error in HOB transmission-waiting
Description Communication failure between CPU and LSI on the DC
Controller PCB (UN1).
Remedy
1. Turn OFF and then ON the power.
2. Replace the DC Controller PCB (UN1).
E197 01B0
05
Title
Timeout error in HOB reception-waiting
Description Communication failure between CPU and LSI on the DC
Controller PCB (UN1).
Remedy
1. Turn OFF and then ON the power.
2. Replace the DC Controller PCB (UN1).
E197 0200
05
Title
Error in communication of HOB DMA mode
Description Communication failure between CPU and LSI on the DC
Controller.
Remedy
1. Turn OFF and then ON the power.
2. Replace the DC Controller PCB (UN1).