
8
8
8-50
8-50
Service Mode > COPIER > DISPLAY > HT-C
Service Mode > COPIER > DISPLAY > HT-C
COPIER > DISPLAY > HT-C
DLTA-C-Y
Dis of ARCDAT screen C Y-density differ
Lv.2 Details
To display the difference between the Y-patch target value and the
current value of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLTA-C-M
Dis of ARCDAT screen C M-density differ
Lv.2 Details
To display the difference between the M-patch target value and the
current value of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLTA-C-C
Dis of ARCDAT screen C C-density differ
Lv.2 Details
To display the difference between the C-patch target value and the
current value of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLTA-C-K
Dis of ARCDAT screen C Bk-density differ
Lv.2 Details
To display the difference between the Bk-patch target value and the
current value of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
TGT-A-Y2
ARCDAT scrn A Y-color target VL(1/2 SPD)
Lv.2 Details
To display the Y-patch target value of screen A in ARCDAT control at
1/2 speed.
Use case
When checking ARCDAT control operation
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
COPIER > DISPLAY > HT-C
TGT-A-M2
ARCDAT scrn A M-color target VL(1/2 SPD)
Lv.2 Details
To display the M-patch target value of screen A in ARCDAT control at
1/2 speed.
Use case
When checking ARCDAT control operation
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-A-C2
ARCDAT scrn A C-color target VL(1/2 SPD)
Lv.2 Details
To display the C-patch target value of screen A in ARCDAT control at
1/2 speed.
Use case
When checking ARCDAT control operation
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-A-K2
ARCDAT scrn A Bk-clr target VL(1/2 SPD)
Lv.2 Details
To display the Bk-patch target value of screen A in ARCDAT control
at 1/2 speed.
Use case
When checking ARCDAT control operation
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-A-Y3
ARCDAT scrn A Y-color target VL(1/3 SPD)
Lv.2 Details
To display the Y-patch target value of screen A in ARCDAT control at
1/3 speed.
Use case
When checking ARCDAT control operation
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-A-M3
ARCDAT scrn A M-color target VL(1/3 SPD)
Lv.2 Details
To display the M-patch target value of screen A in ARCDAT control at
1/3 speed.
Use case
When checking ARCDAT control operation
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-A-C3
ARCDAT scrn A C-color target VL(1/3 SPD)
Lv.2 Details
To display the C-patch target value of screen A in ARCDAT control at
1/3 speed.
Use case
When checking ARCDAT control operation
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-A-K3
ARCDAT scrn A Bk-clr target VL(1/3 SPD)
Lv.2 Details
To display the Bk-patch target value of screen A in ARCDAT control
at 1/3 speed.
Use case
When checking ARCDAT control operation
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700