E020 03B0
05
Title
Error in C Developing Assembly
Description TD ratio lower limit error at the time of print sequence
(Large amount of toner in the Developing Assembly)
Remedy
Go through the following: DISPLAY > DENS > DENS-C; if
DENS-C is slightly higher than 5.0%, output 10 sheets of
solid image with the color causing the error (to reduce T/D
ratio). See the Service Mode again to see if the problem
is improved. Remedy is complete if it’s improved. If not,
perform the following remedy work.
1. Check if the ATR Sensor (TS7) Connector is
disconnected.
2. Check short-circuit of the ATR Sensor Harness.
3. Replace the Developing Assembly.
E020 03B1
05
Title
Error in C Developing Assembly
Description TD ratio upper limit error at the time of print sequence
(Small amount of toner in the Developing Assembly)
Remedy
1. Output 10 sheets of white (blank) sheets (to increase
T/D ratio).
2. Check toner leak from the Toner Buffer Unit.
3. Check toner level in the Toner Container.
4. Replace the Developing Assembly.
5. Check short-circuit of the harness of the Toner supply
sensor (PS3).
E020 0430
05
Title
Error in Bk Developing Assembly
Description The average of ATR reference value was lower than the
specified value at the time of ATR Sensor initialization.
Remedy
1. Check short-circuit of the ATR Sensor (TS8) Harness.
2. Replace the Developing Assembly.
E020 0431
05
Title
Error in Bk Developing Assembly
Description The average of ATR reference value was higher than the
specified value at the time of ATR Sensor initialization.
Remedy
1. Check if the ATR Sensor (TS8) Connector is properly
connected.
2. Check short-circuit of the ATR Sensor Harness.
3. Replace the Developing Assembly.
E020 0440
05
Title
Error in Bk Developing Assembly
Description Unable to adjust the control voltage at the time of ATR
initialization: less than the specified value (3.2V).
Remedy
1. Check if the ATR Sensor (TS8) Connector is properly
connected.
2. Check short-circuit of the ATR Sensor Harness.
3. Replace the Developing Assembly.
E
code
Detailed
code
Occurance
area
Items
Description
E020 0441
05
Title
Error in Bk Developing Assembly
Description Unable to adjust the control voltage at the time of ATR
initialization: exceeds the specified value (6.8V).
Remedy
1. Check short-circuit of the ATR Sensor (TS8) Harness.
2. Replace the Developing Assembly.
E020 0490
05
Title
Error in Bk Developing Assembly
Description Error in signal lower limit with ATR sampling detected
value
Remedy
1. Check if the ATR Sensor Connector is disconnected.
2. Check short-circuit of the ATR Sensor (TS8) Harness.
3. Replace the Developing Assembly.
E020 0491
05
Title
Error in Bk Developing Assembly
Description Error in signal upper limit with ATR sampling detected
value
Remedy
1. Check toner leak from the Toner Buffer Unit.
2. Check toner level in the Toner Container.
3. Replace the Developing Assembly.
4. Check short-circuit of the harness with the Toner Buffer
Supply Sensor (PS4).
E020 04B0
05
Title
Error in Bk Developing Assembly
Description TD ratio lower limit error at the time of print sequence
(Large amount of toner in the Developing Assembly)
Remedy
Go through the following: DISPLAY > DENS > DENS-K; if
DENS-K is slightly higher than 5.0%, output 10 sheets of
solid image with the color causing the error (to reduce T/D
ratio). See the Service Mode again to see if the problem
is improved. Remedy is complete if it’s improved. If not,
perform the following remedy work.
1. Check if the ATR Sensor (TS8) Connector is
disconnected.
2. Check short-circuit of the ATR Sensor Harness.
3. Replace the Developing Assembly.
E020 04B1
05
Title
Error in Bk Developing Assembly
Description TD ratio upper limit error at the time of print sequence
(Small amount of toner in the Developing Assembly)
Remedy
1. Output 10 sheets of white (blank) sheets (to increase
T/D ratio).
2. Check toner leak from the Toner Buffer Unit.
3. Check toner level in the Toner Container.
4. Replace the Developing Assembly.
5. Check short-circuit of the harness of the Toner supply
sensor (PS4).