7
7
7-47
7-47
Error•Jam•Alarm > Error Code > Error Code Details
Error•Jam•Alarm > Error Code > Error Code Details
E
code
Detailed
code
Occurance
area
Items
Description
E56F 0002
05
Title
Entrance Roller Release/Stopper HP Motor fails to return
to HP
Description At initial rotation, when the Motor rotates for specified
period of time and cannot return to HP, it is detected as
an error if the same symptom occurs again after the first
retry.
Remedy
1. Check if the Motor (M6) Connector is physically
removed.
2. Check if the Motor failure occurs.
3. Check if the Entrance Roller Release/Stopper HP
Sensor (S5) Connector is physically removed.
4. Check if the Entrance Roller Release/Stopper HP
Sensor (S5) failure occurs.
E571 0001
05
Title
Gripper Open/Close Motor fails to move from HP
Description At initial rotation, when the Motor rotates for specified
period of time and cannot move from HP, it is detected as
an error if the same symptom occurs again after the first
retry.
Remedy
1. Check if the Motor (M7) Connector is physically
removed.
2. Check if the Motor failure occurs.
3. Check if the Gripper Arm HP Sensor (S13) Connector
is physically removed.
4. Check if the Gripper Unit HP Sensor (S7) failure
occurs.
E571 0002
05
Title
Gripper Open/Close Motor fails to return to HP
Description At initial rotation, when the Motor rotates for specified
period of time and cannot return to HP, it is detected as
an error if the same symptom occurs again after the first
retry.
Remedy
1. Check if the Motor (M7) Connector is physically
removed.
2. Check if the Motor failure occurs.
3. Check if the Gripper Arm HP Sensor (S13) Connector
is physically removed.
4. Check if the Gripper Unit HP Sensor (S7) failure
occurs.
E
code
Detailed
code
Occurance
area
Items
Description
E575 0001
05
Title
Gripper Unit Move Motor fails to move from HP
Description At initial rotation, when the Motor rotates for specified
period of time and cannot move from HP, it is detected as
an error if the same symptom occurs again after the first
retry.
Remedy
1. Check if the Motor (M2) Connector is physically
removed.
2. Check if the Motor failure occurs.
3. Check if the Gripper Unit HP Sensor (S7) Connector is
physically removed.
4. Check if the Gripper Unit HP Sensor (S7) failure
occurs.
E575 0002
05
Title
Gripper Unit Move Motor fails to return to HP
Description At initial rotation, when the Motor rotates for specified
period of time and cannot return to HP, it is detected as
an error if the same symptom occurs again after the first
retry.
Assumed
cause
1. Check if the Motor (M2) Connector is physically
removed.
2. Check if the Motor failure occurs.
3. Check if the Gripper Unit HP Sensor (S7) Connector is
physically removed.
4. Check if the Gripper Unit HP Sensor (S7) failure
occurs.
E584 0002
05
Title
Shutter home position error
Description The stapler does not return to the shutter home position
when the stack ejection motor has been driven for 3
seconds.
Remedy
1. The shutter home position sensor (PI113) is faulty.
2. The shutter mechanism is faulty.
3. The stack ejection motor (M102), shutter clutch
(CL101), ang stack ejection lower roller clutch (CL102) is
faulty.
4. The finisher controller PCB is faulty.
E584 8001
05
Title
Shutter home position error
Description The stapler does not leave the shutter home position
when the stack ejection motor has been driven for 30
seconds.
Remedy
1. The shutter home position sensor (PI113) is faulty.
2. The wiring between the finisher controller PCB and
stack ejection motor, and between the finisher controller
PCB and shutter clutch is faulty.
3. The shutter mechanism is faulty.
4. The stack ejection motor (M102), shutter clutch
(CL101), ang stack ejection lower roller clutch (CL102) is
faulty.
5. The finisher controller PCB is faulty.