Troubleshooting > Version upgrade > Overview > Writing System Software
Troubleshooting > Version upgrade > Overview > Writing System Software
■
Writing System Software
The system software downloaded in either of the above-mentioned methods is stored in the temporary memory space.
After the system software is successfully downloaded, restart the machine to write the software in the machine.
In case the main power switch is turned OFF during the writing process, the machine may not be started.
This machine supports the remote version upgrade via CDS. When upgrading the system software via CDS, the warning message is shown on the control panel to alert the user not to turn OFF the
power switch.
When the system software is successfully written, the machine is automatically restarted to activate the downloaded system software.
If any error occurs during the writing process, the error code, E753-0001, is shown.
The name of the system software component is shown to the left of the error log message, “version up…..error”. Check the name if the software is for the option not attached to the machine. If so,
turn OFF / ON the machine to recover the error (see Troubleshooting for details).