2
2
2-189
2-189
Technology > MEAP > Formatting and Replacing the HDD > Using USB Devices
Technology > MEAP > Formatting and Replacing the HDD > Using USB Devices
Specifications for the use of USB keyboards
Characters that could be entered on the software keyboard displayed on the conventional
control panel can be entered using a USB connected keyboard.
• When the software keyboard window is displayed, characters can be entered from the USB
keyboard (in-line entry not possible).
• When the software keyboard window is not displayed, entered characters will not be
remembered.
• The characters, which can be entered from a USB keyboard, is only a character, which can
be entered from the software keyboard.
• Even if characters are entered from the USB keyboard, the software keyboard window will
not change (the corresponding key does not invert or change color).
• Input from the USB keyboard can be accepted at the same time as input from the software
keyboard or numeric keys.
• Since the device supports Plug and Play, the USB keyboard can be disconnected/
connected freely. However, do not disconnect and connect during in deep sleep (when
in sleep with setting "low" at "the power consumption in sleep"). It is out of an operation
guarantee to disconnect and connect the USB keyboard in deep sleep.
• When USB device is attached to iR device, iR devices do not shift to deep sleep mode.
• Keyboard layout changes according to the keyboard layout settings in the Settings/
Registration screen. In addition, function keys and ten keys which are not displayed in the
software keyboard cannot be used. (Keyboard which the operation check was conducted
is 84-key Keyboard, but this does not mean that the operation of all 84-key Keyboards is
guaranteed.)
Note:
The factory shipment default setting is to enable the use of native (main unit
functionality) USB keyboards. Therefore, in order to use MEAP application keyboards,
[Use MEAP driver for USB input device] under [System management settings (initial
settings/ registration)] needs to be set to ON (factory shipment setting is OFF).
Operations change as described below in accordance with ON/ OFF settings.
ON: when using MEAP application keyboard
OFF: when using native (main unit functionality) keyboard (factory shipment default)
●
Initialization of MEAP driver priority registration
When any trouble occurs regarding USB driver settings and it is necessary to reset the setting
information, you can reset the MEAP driver preference registration by using service mode.
Steps to initialize preference use registration
1) Start [SERVICE MODE] in Level 1.
2) Press [COPIER] > [Function] > [CLEAR] > buttons.
3) Press
or
button for several times until [USBM-CLR] is shown on the screen.
Press [USBM-CLR] button.