8
8
8-240
8-240
Service Mode > FEEDER > ADJUST
Service Mode > FEEDER > ADJUST
FEEDER > ADJUST
LA-SPD2
Fine adj of DADF image magnifictn: back
Lv.1 Details
To adjust the image magnification ratio in vertical scanning direction
for DADF scanning.
As the value is incremented by 1, the image is reduced by 0.01 % in
vertical scanning direction. (The feeding speed increases, and the
image is reduced.)
Use case
- When installing DADF
- When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-200 to 200
Unit
0.01%
Default value
0
ADJMSCN1
Zoom adj in 2-sided horz scan way: front
Lv.1 Details
To make a fine adjustment of the front side image magnification ratio
in horizontal scanning direction at the time of DADF duplex scanning.
As the value is incremented by 1, the image is reduced by 0.1 % in
horizontal scanning direction.
Use case
When a displacement occurs to the front/back side image
magnification ratio at the time of duplex scanning
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-10 to 10
Unit
0.10%
Default value
0
ADJMSCN2
Zoom adj in 2-sided horz scan way: back
Lv.1 Details
To make a fine adjustment of the back side image magnification ratio
in horizontal scanning direction at the time of DADF duplex scanning.
As the value is incremented by 1, the image is reduced by 0.1 % in
horizontal scanning direction.
Use case
When a displacement occurs to the front/back side image
magnification ratio at the time of duplex scanning
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-10 to 10
Unit
0.10%
Default value
0
FEEDER > ADJUST
ADJSSCN1
Zoom adj in 2-sided vert scan way: front
Lv.1 Details
To make a fine adjustment of the front side image magnification ratio
in vertical scanning direction at the time of DADF duplex scanning.
As the value is incremented by 1, the image is reduced by 0.1 % in
vertical scanning direction.
Use case
When a displacement occurs to the front/back side image
magnification ratio at the time of duplex scanning
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-10 to 10
Unit
0.10%
Default value
0
ADJSSCN2
Zoom adj in 2-sided vert scan way: back
Lv.1 Details
To make a fine adjustment of the back side image magnification ratio
in vertical scanning direction at the time of DADF duplex scanning.
As the value is incremented by 1, the image is reduced by 0.1 % in
vertical scanning direction.
Use case
When a displacement occurs to the front/back side image
magnification ratio at the time of duplex scanning
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-10 to 10
Unit
0.10%
Default value
0
T-8-86