Error•Jam•Alarm > Error Code > Error Code Details
Error•Jam•Alarm > Error Code > Error Code Details
E
code
Detailed
code
Occurance
area
Items
Description
E710 0001
05
Title
Error in initialization of IPC (Ctrl)
Description Failed to be at ready status within 3 sec after IPC chip
has been started.
Remedy
Check the connection between DC Controller PCB and
Finisher, and check that the Cable is not open-circuit.
E711 0001
05
Title
Error in IPC communication
Description Initial communication error with the Finisher
Remedy
Check the connector connected to the Finisher.
E713 0001
05
Title
Error in IPC communication
Description When receiving retransmission request for 3 times in a
row.
Remedy
Check the connector connected to the Finisher.
E713 0002
05
Title
Error in IPC communication
Description When detecting CRC error at transmission.
Remedy
Check the connector connected to the Finisher.
E713 0004
05
Title
Error in IPC communication
Description When not receiving data for more than specified time
Remedy
Check the connector connected to the Finisher.
E713 0008
05
Title
Error in IPC communication
Description When checksum of the received data is not correct.
Remedy
Check the connector connected to the Finisher.
E713 0010
05
Title
Error in UFDI communication
Description Neither ACK nor NAK is returned for specified times in a
row.
Remedy
Check the connector connected to the Finisher.
E713 0011
05
Title
Error in UFDI communication
Description NAK is returned for specified times in a row.
Remedy
Check the connector connected to the Finisher.
E713 0020
05
Title
UFDI communication error
Description BCC of the reception data is invalid for specified number
of times in a row.
Remedy
Check the connection of the Connector with Finisher.
E713 0021
05
Title
Error in UFDI communication
Description Timeout before the completion of reception for specified
times in a row.
Remedy
Check the connector connected to the Finisher.
E713 0022
05
Title
Error in UFDI communication
Description Undefined error for specified times in a row at reception.
Remedy
Check the connector connected to the Finisher.
E
code
Detailed
code
Occurance
area
Items
Description
E719 0001
00
Title
Error in Coin Vendor.
Description Error in starting of the CoinVendor
- The Coin Vendor, which should have been connected
before the power was turned OFF, is not connected when
the power is turned ON.
Remedy
Check the connection between charging management
equipment and machine, and check that the Cable is not
open-circuit.
Clear the error while the charging management
equipment is connected to operate and when switching to
the operation without charging management equipment.
(To prevent the misuse by removing the charging
management equipment, this error code is displayed.)
E719 0002
00
Title
Error in Coin Vendor.
Description Error in IPC when CoinVendor is running.
- In the case of disconnection of IPC or an error in which
IPC communication failed to be recovered.
- When disconnection of the pickup delivery signal is
detected.
- When illegal connection is detected (short-circuit with
Tx and Rx of IPC)
Remedy
Check the connection between charging management
equipment and machine, and check that the Cable is not
open-circuit.
Clear the error while the charging management
equipment is connected to operate and when switching to
the operation without charging management equipment.
(To prevent the misuse by removing the charging
management equipment, this error code is displayed.)
E719 0003
00
Title
Error in Coin Vendor.
Description - In the case of communication error with the coin vendor
while obtaining the unit price at start-up.
Remedy
Check the connection between charging management
equipment and machine, and check that the Cable is not
open-circuit.
Clear the error while the charging management
equipment is connected to operate and when switching to
the operation without charging management equipment.
(To prevent the misuse by removing the charging
management equipment, this error code is displayed.)