SuperTrak™ GEN3 System Operation and Maintenance Manual
251
Rev. 9 (12-2021)
Troubleshooting
This section provides the following SuperTrak conveyance platform troubleshooting
procedures for qualified technicians:
•
•
•
•
•
Test Straight Section or Curved Section Hardware
•
Read and understand the SuperTrak conveyance platform process and safety
guidelines before starting any troubleshooting procedures.
Communication Faults
Fault
Resolution
The configuration software is
unable to connect to the
controller.
• Attempt to retrieve diagnostic information using the
following website:
http://controller_IP_address/sdm
The IP address of the controller is required for this
procedure.
• Check the controller LEDs.
A fault message indicates that
a communication problem
exists.
1. Read the fault message, and reference the TrakMaster
built-in help for a resolution.
See
Access the TrakMaster Built-in Help
2. Verify that all associated electronic components have
power (for example; confirm power by looking at the
component indicator lights).
3. Turn the power OFF to the controller and gateway boards
(24V digital power).
4. Verify that all associated cables are correctly connected.
Make sure the cable connections are correct to the
components, and that the connectors are seated correctly
at both ends.
See
5. Turn the power ON.
Summary of Contents for SuperTrak GEN3
Page 1: ...Rev 9 December 2021...
Page 2: ......
Page 3: ...SuperTrak GEN3 Conveyance Platform Modular Conveyor Operation and Maintenance Manual...
Page 6: ......
Page 12: ...This page is intentionally blank...
Page 30: ...This page is intentionally blank...
Page 58: ...This page is intentionally blank...
Page 296: ...This page is intentionally blank...
Page 300: ...This page is intentionally blank...
Page 364: ...This page is intentionally blank...
Page 366: ...This page is intentionally blank...