146
SuperTrak™ GEN3 System Operation and Maintenance Manual
Rev. 9 (12-2021)
Technician Procedures
Replace or Install a New Power Supply
1. Turn the
SuperTrak conveyance platform power disconnect switch
to
the OFF position.
2. Lock out and tag hazardous energy.
3. If you are installing a new power supply, complete the following steps:
a. Determine the power supply installation location.
b. Drill and tap four (4) holes into the frame.
The holes must align with the mounting plate holes.
c. Secure the mounting plate to the frame with four (4) screws.
d. As required, remove the black plug in the section before connecting.
e. Proceed to step 5.
4. If you are replacing an existing power supply:
a. Remove the four (4) screws that secure it to the mounting plate.
b. Disconnect the power supply wire connections from the SuperTrak
conveyance platform (not from the power supply).
5. Secure the new power supply to the mounting plate with one (1) screw in each
of the four (4) mounting brackets.
6. As required, complete one (1) of the following to access the left coil driver
board:
•
For all straight, 180 deg. (800 mm), and 90 deg. sections: Open the
electrical door at the base of the section’s motor.
Summary of Contents for SuperTrak GEN3
Page 1: ...Rev 9 December 2021...
Page 2: ......
Page 3: ...SuperTrak GEN3 Conveyance Platform Modular Conveyor Operation and Maintenance Manual...
Page 6: ......
Page 12: ...This page is intentionally blank...
Page 30: ...This page is intentionally blank...
Page 58: ...This page is intentionally blank...
Page 296: ...This page is intentionally blank...
Page 300: ...This page is intentionally blank...
Page 364: ...This page is intentionally blank...
Page 366: ...This page is intentionally blank...