172
SuperTrak™ GEN3 System Operation and Maintenance Manual
Rev. 9 (12-2021)
Technician Procedures
Replace a Thermistor - 180 Deg. Section (500 mm)
There are six (6) thermistors in each 180 deg. section.
1. Turn the
SuperTrak conveyance platform power disconnect switch
to
the OFF position.
2. Lock out and tag hazardous energy.
3. Remove the 180 deg. section top cover.
4. Unplug the thermistor connector from the coil driver board.
5. Pull the old thermistor wire straight out from the thermistor hole.
6. Slide the end of the new thermistor wire into the thermistor hole until you feel
resistance.
The thermistor tapers. During installation, the thick ridge creates a friction fit
against the sides of the thermistor hole
7. Plug the new thermistor connector into the electrical board.
8. Route the thermistor wire under the electrical board.