Appendix C: Component Data Sheets
SuperTrak™ GEN3 System Operation and Maintenance Manual
311
Rev. 9 (12-2021)
Pallet Magnetic Field Strength Measurement Locations
2-Magnet Pallet Magnetic Measurement Values
All measurements in the following table are in Gauss units.
See
Pallet Magnetic Field Strength Measurement Locations
magnetic field strength measurement locations, and
for a description of X, Y, and Z
.
2-Magnet Pallet Enabled at a
Standstill
2-Magnet Pallet at Peak Force
a
Location
X
Y
Z
X
Y
Z
A
14
10
10
117
157
149
B
3
3.5
2.5
15
17
36
C
14
10
10
117
157
149
D
8
8
23
180
249
221
E
17
3
21
140
268
171
F
13
15
32
180
200
155
G
13
11
6
55
60
30
H
13
11
6
55
60
30
I
2.8
2.7
2.5
2.8
2.7
7
J
2.8
2.7
2.5
2.8
2.7
7
K
10
10
10
45
40
51
L
10
10
10
45
40
51