Technician Procedures
SuperTrak™ GEN3 System Operation and Maintenance Manual
147
Rev. 9 (12-2021)
•
For 180 deg (500 mm) sections: Remove the top cover from the 180
deg. (500 mm) section. It may also be helpful to remove the panel on
the back of the section.
7. Feed the 28 VDC power output cable
through the plug opening (step 3d) and
then tighten the connection.
8. Connect the power supply cables to the left coil driver board:
a. Remove the screw from the top of
the 50A fuse, and the screw from
the common connection wire.
b. Align the positive (+) 28VDC
motor power wire of the power
supply with the top of the 50A
fuse.
c. Secure the wire and fuse in
position with a lock nut, washer,
and screw.
Summary of Contents for SuperTrak GEN3
Page 1: ...Rev 9 December 2021...
Page 2: ......
Page 3: ...SuperTrak GEN3 Conveyance Platform Modular Conveyor Operation and Maintenance Manual...
Page 6: ......
Page 12: ...This page is intentionally blank...
Page 30: ...This page is intentionally blank...
Page 58: ...This page is intentionally blank...
Page 296: ...This page is intentionally blank...
Page 300: ...This page is intentionally blank...
Page 364: ...This page is intentionally blank...
Page 366: ...This page is intentionally blank...