256
SuperTrak™ GEN3 System Operation and Maintenance Manual
Rev. 9 (12-2021)
Troubleshooting
Check Coil Resistance to Find Shorted or Mis-wired
Coils
Use a multimeter to check for shorted or mis-wired coils.
Instruction
Graphic
Desired Result/Action
1. Turn the SuperTrak power supply power OFF.
2. Detach the first green
terminal block plug
from the coil driver
board and use a
multimeter to check
the resistance
between the 1st and
2nd pin (first and
second as counted
from the left).
A resistance range of
0.1-0.6
Ω
(
Ohms)
indicates that the coil is
functioning properly.
3. Check the resistance
between the 3rd and
4th pin.
A resistance range of
0.1-0.6
Ω
indicates that
the coil is functioning
properly.
4. Check the resistance
between the 1st and
4th pin.
This should be open or
no connection. You may
see varying resistance
measured on the
multimeter, but it should
not settle on a specific
measurement. If the
multimeter does settle
on a resistance amount,
it means the coils are
mis-wired and must be
wired correctly to avoid
blowing fuses.
Summary of Contents for SuperTrak GEN3
Page 1: ...Rev 9 December 2021...
Page 2: ......
Page 3: ...SuperTrak GEN3 Conveyance Platform Modular Conveyor Operation and Maintenance Manual...
Page 6: ......
Page 12: ...This page is intentionally blank...
Page 30: ...This page is intentionally blank...
Page 58: ...This page is intentionally blank...
Page 296: ...This page is intentionally blank...
Page 300: ...This page is intentionally blank...
Page 364: ...This page is intentionally blank...
Page 366: ...This page is intentionally blank...