Installation
SuperTrak™ GEN3 System Operation and Maintenance Manual
59
Rev. 9 (12-2021)
16. Install the first curved section.
17. For 180 deg. sections, use shims to verify that a 0.5 mm (0.02 in.) gap exists
between the 180 deg. section and each of the two (2) abutting straight sections
(between the track structure [or aluminum extrusion], not between the linear
motors [or motor laminations]).
For 90 degree sections, use shims to verify that a 0.5 mm (0.02 in.) gap exists
between the 90 deg. section and each of the two (2) abutting sections.